Mesures 7
Logamax plus GB022-24K - Sous réserve de modifications techniques.
51
Section 100
z Nettoyer l’ailette.
Section 101
z Remonter la partie supérieure de la pompe de circulation.
z Remplir et purger l’installation de chauffage
(Æ Paragraphe 52 59).
z Monter l’habillage (Æ Paragraphe 51).
Section 102 Remplacer la pompe de circulation
HDANGER DE MORT
par électrocution !
z Mettre la chaudière hors service et vidanger l'installation
(Æ Paragraphe 42, 43, 46, 44, 48 ou 49).
z Démonter la fiche d'alimentation électrique de la pompe
de circulation (Æ Paragraphe 93).
Section 103
z Dévisser les deux écrous-raccords [1] sur la partie
supérieure et inférieure de la pompe.
z Retirer la pompe.
1
1
Section 104
AATTENTION !
Pour le montage de la nouvelle pompe, utiliser des
anneaux d'étanchéité plats neufs.
z Monter la nouvelle pompe de circulation.
z Insérer la fiche de courant de la pompe, remplir et purger
l'installation puis mettre la chaudière en marche
(Æ Paragraphe 58 61).
z Monter l’habillage (Æ Paragraphe 51).
Section 105Contrôler les sondes de départ, de
température de sécurité et de température
ECS (uniquement avec préparateur externe)
z Mettre la chaudière en marche (Æ Paragraphe 55 ou 56).
z Ouvrir le robinet d'eau chaude puis, une fois que la
chaudière a démarré, attendre que la température de
départ chauffage dépasse 80 °C en refermant peu à peu
le robinet d'eau chaude.
z Démonter l'habillage et mettre la chaudière hors service
(Æ Paragraphe 42, 43 ou 46).
Section 106
z Détacher la fiche de la sonde de température de sécurité.
51


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamax plus GB022-24K at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamax plus GB022-24K in the language / languages: French as an attachment in your email.

The manual is 5,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logamax plus GB022-24K

Buderus Logamax plus GB022-24K Installation Guide - French - 52 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info