Anhang 8
Änderungen aufgrund technischer Verbesserungen vorbehalten! Bosch Thermotechnik GmbHhttp://www.buderus.de
Serviceanleitung Logamax plus GB162-80/100 • Ausgabe 03/2008 105
Abschnitt 307
Abschnitt 308
Abschnitt 309
Displayanzeige des
Basiscontrollers
BC10 [%]
Nennleistung bei 40/30 °C
[kW]
Logamax plus
GB162-80
Logamax plus
GB162-100
Land DE/AT/LU BE DE/AT/LU BE
L20 21,1
L25 21,1 26,0 26,0
L30 25,3 26,0 30,9 30,9
L35 29,6 30,2 35,8 35,8
L40 33,8 34,4 40,7 40,7
L45 38,0 38,5 45,6 45,6
L50 42,2 42,7 50,5 50,5
L55 46,5 46,9 55,4 55,4
L60 50,7 51,1 60,3 60,3
L65 54,9 55,2 65,2 65,2
L70 59,1 59,4 70,1 70,1
L75 63,4 63,6 75,0 75,0
L80 67,6 67,8 79,9 79,9
L85 71,8 72,0 84,8 84,8
L90 76,0 76,1 89,7 89,7
L95 80,3 80,3 94,6 94,6
L-- 84,5 84,5 99,5 99,5
Widerstandswerte der Fühler
Temperatur in
°C
Widerstand
in
Ω
Temperatur in
°C
Widerstand
in
Ω
0 29.490
5 23.462 80 1.458
10 18.787 85 1.255
15 15.136 90 1.084
20 12.268 95 940
25 10.000 100 817
30 8.197 105 714
35 6.754 110 626
40 5.594 115 550
45 4.656 120 484
50 3.893 125 428
55 3.271 130 379
60 2.760 135 337
65 2.339 140 300
70 1.990 145 268
75 1.700 150 239
Gasanschlussdruck [mbar]
Gasband Gasart Land P
min
P
n
P
max
Erdgas
E G20 DE/AT/LU 17 20 25
Erdgas
E(S)B G20 BE 172025
Erdgas
E(S)B G25 BE 172530
Erdgas
LL G25 DE 182025
Fl
ussiggas P G31 BE 253745
Fl
ussiggas P G31 DE/AT/LU 42,5 50 57,5
Abschnitt 310
Kontakt Widerstand [Ω]
4 - 6 51,1 ±10 %
4 - 5 28,4 ±10 %
13 - 14 1,58 ±10 %
14 - 15 1,78 ±10 %
16 - 17 2,47 ±10 %
18 - 19 574 ±10 %
105


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamax plus GB162-80 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamax plus GB162-80 in the language / languages: German as an attachment in your email.

The manual is 7,01 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logamax plus GB162-80

Buderus Logamax plus GB162-80 User Manual - English - 36 pages

Buderus Logamax plus GB162-80 Installation Guide - German - 96 pages

Buderus Logamax plus GB162-80 User Manual - German - 12 pages

Buderus Logamax plus GB162-80 Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info