697449
21
Zoom out
Zoom in
Previous page
1/60
Next page
Logamatic EMS RC35 programming unit - Subject to technical modifications
21
Commissioning
5
5.4 Detailed commissioning
B Check whether the factory settings in menu SERVICE\SETTINGS suit your heating system.
B Note down modified settings if needed.
5.5 System handover
B Ensure that no temperature limits for central heating and DHW have been set at the boiler
programming unit, so DHW and flow temperature can be regulated via the RC35 programming
unit.
B Explain to the customer how the device works and how to operate it.
B Inform customer about the selected settings.
DHW Have you installed
domestic hot water?
yes, no no
4)
What should be used
for domestic hot water
heating?
3-way
switching
valve
cylinder
primary
pump
3-way
switching
valve
5)
To which temperature
should your domestic
hot water be heated?
30 °C to
80 °C
60 °C To be able to change the
DHW temperature, set
DHW on the boiler
programming unit to
“AUT” or enable DHW.
SOLAR MODULE Have you installed a
solar module?
yes, no no
1)
1) Not possible or available on boilers with UBA1.x or DBA.
2) Not possible on boilers with UBA4.
3) Only possible on boilers with UBA4.
4) Not possible or not available with boilers with DBA.
5) Not available with boilers with UBA1.x, DBA or UBA-H3.
Check whether further settings are required using the checklist on page 19.
SHORTCUT\ Menu item
Input
range
Factory
setting Other information
Tab. 8 Quick operation menu navigator
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamatic EMS RC35 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamatic EMS RC35 in the language / languages: English as an attachment in your email.

The manual is 2,02 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logamatic EMS RC35

Buderus Logamatic EMS RC35 User Manual - English - 60 pages

Buderus Logamatic EMS RC35 Installation Guide - German - 60 pages

Buderus Logamatic EMS RC35 User Manual - German - 60 pages

Buderus Logamatic EMS RC35 User Manual - Dutch - 60 pages

Buderus Logamatic EMS RC35 Installation Guide - Dutch - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info