Troubleshooting
11
Logamatic 4321/4322 - Subject to technical modifications.
72
11 Troubleshooting
Have your heating engineer remedy all faults
immediately.
All system faults are displayed on the MEC2
programming unit.
Report the fault by telephone to your heating contractor.
Where necessary, set the module switches according to
the instructions in Chapter 12.
Provided your control unit is equipped with the above
modules, the following faults may be reported:
Burner fault boiler
Boiler temperature sensor
Outside temperature sensor
Heating circuit flow sensor
heating circuit 1 – 8 (if installed)
DHW temperature sensor
Boiler is cold
DHW stays cold
DHW warning
Remote control no communication with
heating circuit 1 – 8 (if installed)
Thermal Disinfection
Auxiliary temperature sensor
Heating circuit 1 – 8 (if installed) pump fault
DHW pump fault
DHW inert anode fault
Safety equipment fault
No connection to the BUS system
Address used more than once
External boiler fault
Flue gas sensor fault
Flue gas temperature exceeded
Address conflict slot 1 – 4 (if installed)
Wrong module slot 1 – 4 (if installed)
Unknown module slot 1 – 4 (if installed)
Function module not connected
No master control unit installed
Heating circuit 1 – 8 (if installed) in manual mode
DHW in manual mode
Boiler circuit in manual mode
Burner in manual mode
72


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamatic 4322 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamatic 4322 in the language / languages: English as an attachment in your email.

The manual is 1,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info