557439
75
Zoom out
Zoom in
Previous page
1/80
Next page
Operation in the event of a fault
12
Logamatic 4211 - Subject to technical modifications.
75
Tab. 5 Settings for emergency operation
Manually disconnect the heating circuit mixer and
position towards "Open" or "Closed" (prevent re-
engagement) so that the required room temperature is
achieved. To prevent the DHW freezing inside the
heating system, never fully close the heating circuit
mixer.
In case of faults, immediately notify your heating
contractor who will guarantee a professional service.
It is helpful for your heating contractor if you can provide
precise details about the fault.
Fault Settings for emergency operation
ON/OFF switch Switch heating circuit
and DHW ZM422
Boiler water
thermostat
Switch, heating circuit
module
FM442
Central heating failed
Heating circuits failed
R
AUT 60 °C 90 °C 3
DHW heating failed
Heating circuits supplied normally
R
3 60 °C AUT
Boiler operation failed
R
3 90 °C AUT
75


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus Logamatic 4211 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus Logamatic 4211 in the language / languages: English as an attachment in your email.

The manual is 2,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus Logamatic 4211

Buderus Logamatic 4211 User Manual - German - 56 pages

Buderus Logamatic 4211 User Manual - Dutch - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info