557395
50
Zoom out
Zoom in
Previous page
1/50
Next page
705.259A - 2600 - 04/2002
Min./Max. settings
10 / 25
YES / NO
RR / WD / WD+RTC
1 / 2 / 3 / 4 / N / A
10 / 90
10 / 90
0 / 10
0 / 120
0 / 120
1 / 2 / 3
-99 / 99
SLO / FAST
ON / OFF / AUTO
ON / OFF / AUTO
RR / WD+RTC
21 °C
19 °C
21 °C
ECO
21 °C
ECO
Your settings
(by installer)
(refer to paragraph 6.2)
(refer to paragraph 7.2)
(refer to paragraph 8.1)
(refer to paragraph 4.6)
(refer to paragraph 4.5)
CV menu
ECO-temperature
Advanced heat-up
Kind of temperatur regelation
Installation type
Starting point of the firing characteristic
Endpoint of the firing characteristic
Room influence
Minimum CH water temperature
Hot water menu
Advanced heat water heat-up
Hot water stop delay
Configuration settings
PID number
Correction of the clock speed
Slow temperature rise
Other settings
Hot water
Heating
Standard clock
Monday to Friday 7.00
9.00
17.00
23.00
Saturday and Sunday 8.00
23.00
Settings of the IRT 30
Standard setting
16 °C
YES
RR
N/A
Refer to Table A
10 °C
30 min.
30 min.
1
0
FAST
ON
ON
WD
+1
-1
+1
-4
+1
-4
Table A Standard settings for different types of installation
Installation Type Starting point End point Room influence
1. Radiators 20 °C 75 °C 6
2. Convectors 40 °C 90 °C 8
3. Thermostatic radiator valves in the living room 30 °C 80 °C 0
4. Only floor heating (no radiators or convectors) 20 °C 50 °C 4
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Buderus iRT 30 - Moduline 30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Buderus iRT 30 - Moduline 30 in the language / languages: English as an attachment in your email.

The manual is 0,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Buderus iRT 30 - Moduline 30

Buderus iRT 30 - Moduline 30 User Manual - German - 51 pages

Buderus iRT 30 - Moduline 30 User Manual - Dutch - 50 pages

Buderus iRT 30 - Moduline 30 User Manual - French - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info