820873
50
Zoom out
Zoom in
Previous page
1/64
Next page
User and installation manual
www.bticino.com
Classe100 X16E with Netatmo
344682 - 344782 - 344932 - 344786
RA00169AD-05/23-PC
Classe100 X16E
User and installation manual
3
Contents
Classe100 X16E
User and installation manual
Quick guide 4
Answer a call 4
Auto-switching on and camera scrolling 6
Call another room or apartment (intercom) 8
General information 10
Warnings and recommendations 10
Warnings and consumer rights 11
Front view 12
Function keys and status LEDs 12
Rear view 14
Installation 15
Dimensional data and recommended installation heights 15
Wall-mounted installation 15
Installation on the tabletop bases 344692 (optional) 17
Configuration 19
Programming of the programmable keys 20
Use from the device 27
Functions 27
Answer a call 27
Call another room or apartment (intercom) 29
PE or cameras direct auto-switching on 31
NETATMO cameras 33
Door lock release 36
Paging 37
Services 38
Inductive loop (only item 344682) 38
Door status 39
Professional Studio (Office) 40
Safe door lock 41
Device adjustments and settings 42
Use of the joystick 42
Wi-Fi adjustments and settings 43
Settings 54
Remote use 57
Association of Classe100 X16E with Home+Security app 57
Quick guide
4
Classe100 X16E
User and installation manual
12
3
Quick guide
Answer a call
1.
Touch to answer the call.
2.
If necessary, during the call press the joystick to display the audio/video parameter adjustment
icons.
3.
Move the joystick up/down to select the type of parameter for which you want to modify the
value (see the following table) among:
Speaker volume (Parameter that can be adjusted only with active audio);
Image brightness;
Image contrast;
Image colour.
Quick guide
54
Classe100 X16E
User and installation manual
4
5
5.
Touch to end the call.
4.
Touch to open the main Entrance Panel door lock
Quick guide
6
Classe100 X16E
User and installation manual
3
1
2
Auto-switching on and camera scrolling
Note: switching from one camera to another is also possible without enabling the audio.
2. If necessary, touch to activate the audio communication
3. Touch to display another Entrance Panel or camera (using the scrolling service). When
switching from one camera to the next the key lights up.
1. Touch to display the Entrance Panels or the cameras in your system.
Quick guide
76
Classe100 X16E
User and installation manual
4
4. Touch to end camera display mode, or wait for the automatic switch off time to elapse.
Quick guide
8
Classe100 X16E
User and installation manual
Call another room or apartment (intercom)
1
Key (A) lights up to indicate that the call is active.
1. For example, touch programmable key to activate the communication with the Internal Unit
(e.g. configured as 2)
Note: the programmable key to use for calling a certain Internal Unit is set by the installer (see
Programming of the programmable keys).
A
#2
Quick guide
98
Classe100 X16E
User and installation manual
When the Internal Unit answers, the key starts flashing. Touch it to end the call or establish
communication with the Internal Unit.
Note: if during the conversation a call is received from the Entrance Panel, the conversation is
interrupted in order to answer the Entrance Panel call.
#2
10
Classe100 X16E
User and installation manual
General information
Warnings and recommendations
The Classe100 X16E video internal unit must be connected to a Wi-Fi network with the following
features:
IEEE 802.11 b/g/n (2,4 GHz) 13 channels
Encrypting and authentication methods supported:
OPEN WPA-PSK networks
TKIP WPA2-PSK included
included AES WEP 64 bits (ASCII 5 figure or hexadecimal 10 figure codes)
WEP 128 bits (ASCII 13 figure or hexadecimal 26 figure codes)
WPS authentication (supported for WPA2-PSK)
It is important to read this manual carefully before proceeding with the installation.
The warranty becomes automatically void in case of negligence, improper use, tampering by
unauthorised personnel.
The Classe100 X16E video internal unit must only be installed indoors; it must not be exposed to
water drops or splashes; it must be used only on BTicino 2 WIRES digital systems.
Note: a domestic Wi-Fi with internet access is needed for the connection between the Classe100 X16E
video internal unit and the smartphone.
To use the service, the Customer must acquire the technical equipment which allows access to the
Internet, on the basis of an agreement made by the Customer himself with an ISP (Internet Service
Provider). BTicino plays no part in this.
The customer must install the Home + Security app on his smartphone so that he can use some services
which BTicino supplies as extras to the normal basic functions of the Classe100 X16E.
The services offered by means of the app require being able to interact with Classe100 X16E remotely
and through the Internet.
In these cases the integration and good working between Classe100 X16E and app may depend on:
a) quality of the Wi-Fi signal;
b) type of access contract to the home internet;
c) type of data contract on the smartphone;
d) configuration of the router.
When one of these 4 elements does not conform with the specifications required for product operation,
BTicino accepts no responsibility for any faults.
The Home + Security app operation with screen off (background) may be compromised by the
applications installed on the smartphone that:
optimise the use of the battery and the energy saving;
protect the device (antivirus or similar programs)
The product in fact supports a VoIP streaming system. You must therefore check with your smartphone
data network contract that it does not block it.
We would like to inform you that the service provided by BTicino by means of remote use via the app
involves the use of data. The cost linked to data usage depends on the type of contract which the
customer has with his ISP (Internet Service Provider) and is solely the customer’s responsibility.
Note: this device includes the Open Source software. For license and software information, connect
your Windows/Linus PC to the device through the mini-USB port.
1110
Classe100 X16E
User and installation manual
Warnings and consumer rights
Read carefully before use and keep for future reference
Touching the units with wet hands is forbidden.
Using liquid cleaners or aerosols is forbidden.
Blocking the ventilation openings is forbidden.
Modifying the devices is forbidden.
Removing protective parts from the devices is forbidden.
Exposing the unit to water drops or splashes is forbidden.Installing the units near
heat/cold sources or hot/cold air emission points is forbidden.
Installing the units near heat/cold sources is forbidden.
Installing the units near harmful gases and powders is forbidden.
Fastening the units on unsuitable surfaces is forbidden.
Danger of electrical shock
Risk of devices falling because the surface on which they are installed collapses
or inappropriate installation
Switch the power supply OFF before any work on the system
Remote operation may cause damage to people or property.
Caution: Installation, configuration, starting-up and maintenance must be
performed exclusively by qualified personnel.
Check that the wall installation has been carried out correctly according to the
installation instructions.
Check that the unit installation complies with the standards in force.
Connect the power supply wires as indicated.
Use only the items indicated in the technical specifications for any system
expansions.
12
Classe100 X16E
User and installation manual
1
2
3
4
1. 5” (16:9) display
2. Speaker
3. Tactile guides for the blinds
4. Microphone
Front view
Function keys and status LEDs
Note: when pressed, the keys light up and emit a “beep” (that can be deactivated using the procedure).
Note: the device initialisation procedure can last up to 2 minutes.
Icon Meaning
Wi-Fi signal notification LED:
When it is OFF, the Wi-Fi is disabled or works correctly.
When it flashes red it indicates that the Wi-Fi is active but not connected to a
network.
When green and on steady, Classe100 X16E is exchanging data with the Home +
Security APP (Entrance Panel call/Automatic Switching On/Call Home)
Bell exclusion notification LED:
When on red flashing, it means that the call ringtone is disabled,
Programmable touch keys *
Use these keys for intercom calls, activate Entrance Panels and Door Locks. The
functions that can be completed depend on the configuration set by the installer
(see Programming of the programmable keys).
Door lock release touch key *
During the connection with an Entrance Panel, use this key to release the door
lock of that Entrance Panel, when idle, the same key releases the door lock of the
associated Entrance Panel. When on white flashing, it means that the Professional
Studio function is active.
1312
Classe100 X16E
User and installation manual
Entrance panel/scrolling activation touch key
This key has two functions: It can be used to switch on the camera of the
associated Entrance Panel, and to scroll through the connected cameras and/or
entrance panels.
Communication disabling key
Use this key to answer a call: when a call is answered, it switches on red; when the
call is terminated it switches off.
Staircase light touch key
Use this key to switch the Staircase Light on
Communication enabling key
Use this key to answer a call: when a call is received, the key starts flashing, once
the call is answered the light switches off.
* If the LEDs flash white when pressed, the “safe door lock” service is active and the key is deactivated.
14
Classe100 X16E
User and installation manual
45
PM
N
BTICINO
V.le Borri, 231
21100 (VA) ITALY
Made in Italy
2 1 5M 1 BUS
2-1
ON OFF
1
2
3
678910
Rear view
1. Mini USB socket for device Firmware update
2. OFF / ON micro-switch for safe door lock” service
ON=
Note: to activate the service with device not powered
3. Configurator socket
4. Line termination ON/OFF micro-switch
5. ON / OFF micro switch to enable the additional power supply
6. 2 WIRES SCS/BUS connection clamps
7. Clamps for the connection of an external call to the floor pushbutton
PM
N
BTICINO
V.le Borri, 231
21100 (VA) ITALY
Made in Italy
2 1 5M 1 BUS
2-1
ON OFF
MasterSlave
ON CTS
12
8. Additional bell connection clamps (5M – 1). The connection must be point - point on the
clamps of the additional bells
9. Additional power supply clamps (2– 1)
10. Joystick for adjustments ans programming
1514
Classe100 X16E
User and installation manual
160 – 165 cm
135 – 140 cm
164 mm
165 mm
20,5 mm
1
Box
502E - 503E
1
Ø max 5 mm
Installation
Dimensional data and recommended installation heights
Wall-mounted installation
Recommended height, unless different regulations are specified.
Caution: Installation, configuration, starting-up and maintenance must be performed
exclusively by qualified personnel.
16
Classe100 X16E
User and installation manual
7
6
5
2
4
3
1716
Classe100 X16E
User and installation manual
Installation on the tabletop bases 344692 (optional)
1
2
6
3
5
4
18
Classe100 X16E
User and installation manual
3X 2
1
2
1918
Classe100 X16E
User and installation manual
N P M
Configuration
The device must be only physically configured.
N - Internal Unit number
The configurators connected to the N sockets of the device assign an identification number within
the system to each video internal unit . The internal units must be configured in progressive order.
Internal units with parallel connection (max 3 are allowed inside apartments without item 346850)
must be configured using the same N configurator. In parallel with the main video internal unit,
additional internal units, video internal units and/or ringtones may be installed.
P – Entrance Panel association
The configurators connected to the P sockets of the device identify the associated EP, which is the
first Entrance Panel that switches itself on when the pushbutton is pressed the first time, as well as
which door lock is activated when pressing the door lock pushbutton while the video internal unit
is idle.
M – operating mode
The configurators connected to the M sockets of the device assign the operating modes to
the 4 programmable keys ( , , , ) based on the indications of the Programming of the
programmable keys table.
They can also enable special functions that entail the activation of the professional studio
and paging functions, individually or at the same time, in addition to the functions already
programmed for the key.
SPECIAL FUNCTIONS
Key Internal
intercom
Professional Studio
(Office) Paging
CONFIGURATOR M
0 0
2 0
4 0
8 0
Example
20
Classe100 X16E
User and installation manual
Programming of the programmable keys
Your Classe100 X16E is equipped with keys that perform specific functions depending on the configurator connected to the M socket.
MODE KEY SERVICE NOTES
M = 00
Internal intercom It sends the call to all the
handsets with the same address
Activation of the EP (configured with P+1) directly
without call or activation of the actuator 346210
(configured with P+1 and MOD=9)
EP door lock release (configured with P+1),
directly without call, or activation of the actuator
346210 (configured with P+1 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+1)
EP door lock release (configured with P+2),
directly without call, or activation of the actuator
346210 (configured with P+2 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+2)
M = 20 Key functions described above + Professional studio
M = 40 Key functions described above + Pager
M = 80 Key functions described above + Professional studio + Pager
M = 01
Internal intercom It sends the call to all the
handsets with the same address
Intercom inside the apartment, in systems with
apartment interface 346850, or intercom among
apartments in systems without apartment
interface
N=1
N=2
N=2
N=1
Activation of the EP (configured with P+1) directly
without call or activation of the actuator 346210
(configured with P+1 and MOD=9)
EP door lock release (configured with P+1),
directly without call, or activation of the actuator
346210 (configured with P+1 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+1)
M = 21 Key functions described above + Professional studio
M = 41 Key functions described above + Pager
M = 81 Key functions described above + Professional studio + Pager
2120
Classe100 X16E
User and installation manual
MODE KEY SERVICE NOTES
M = 02
Intercom inside the apartment, in systems with
apartment interface 346850, or intercom among
apartments in systems without apartment
interface
N=1 N=3 N=2 N=1
N=3 N=1
Intercom inside the apartment, in systems with
apartment interface 346850, or intercom among
apartments in systems without apartment
interface
N=1 N=2 N=2 N=3
N=3 N=2
EP door lock release (configured with P+1),
directly without call, or activation of the actuator
346210 (configured with P+1 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+1)
EP door lock release (configured with P+2),
directly without call, or activation of the actuator
346210 (configured with P+2 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+2)
M = 22 Key functions described above + Professional studio
M = 42 Key functions described above + Pager
M = 82 Key functions described above + Professional studio + Pager
22
Classe100 X16E
User and installation manual
MODE KEY SERVICE NOTES
M = 03
Intercom inside the apartment, in systems with
apartment interface 346850, or intercom among
apartments in systems without apartment
interface
N=1 N=5 N=2 N=1 N=3 N=1
N=4 N=1 N=5 N=1
Intercom inside the apartment, in systems with
apartment interface 346850, or intercom among
apartments in systems without apartment
interface
N=1 N=2 N=2 N=5 N=3 N=2
N=4 N=2 N=5 N=2
Intercom inside the apartment, in systems with
apartment interface 346850, or intercom among
apartments in systems without apartment
interface
N=1 N=3 N=2 N=3 N=3 N=5
N=4 N=3 N=5 N=3
Intercom inside the apartment, in systems with
apartment interface 346850, or intercom among
apartments in systems without apartment
interface
N=1 N=4 N=2 N=4 N=3 N=4
N=4 N=5 N=5 N=4
M = 23 Key functions described above + Professional studio
M = 43 Key functions described above + Pager
M = 83 Key functions described above + Professional studio + Pager
2322
Classe100 X16E
User and installation manual
MODE KEY SERVICE NOTES
M = 04 Activation of the EP (configured with P+1) directly
without call or activation of the actuator 346210
(configured with P+1 and MOD=9)
Intercom inside the apartment, in systems with
apartment interface 346850, or intercom among
apartments in systems without apartment
interface
N=1
N=2
N=2
N=1
EP door lock release (configured with P+1),
directly without call, or activation of the actuator
346210 (configured with P+1 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+1)
EP door lock release (configured with P+2),
directly without call, or activation of the actuator
346210 (configured with P+2 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+2)
M = 24 Key functions described above + Professional studio
M = 44 Key functions described above + Pager
M = 84 Key functions described above + Professional studio + Pager
M = 05 EP door lock release (configured with P+1),
directly without call, or activation of the actuator
346210 (configured with P+1 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+1)
EP door lock release (configured with P+2),
directly without call, or activation of the actuator
346210 (configured with P+2 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+2)
EP door lock release (configured with P+1),
directly without call, or activation of the actuator
346210 (configured with P+1 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+1)
EP door lock release (configured with P+2),
directly without call, or activation of the actuator
346210 (configured with P+2 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+2)
M = 25 Key functions described above + Professional studio
M = 45 Key functions described above + Pager
M = 85 Key functions described above + Professional studio + Pager
24
Classe100 X16E
User and installation manual
MODE KEY SERVICE NOTES
M = 06
Preset intercom function with
intercommunicating call to the Handset
configured with N=1.
From the system handsets it is possible to send an
intercom call to the handset configured with N= 1.
The indoor unit configured with N=1 can receive
intercom calls, but is unable to send them
Internal intercom It sends the call to all the
handsets with the same address
EP door lock release (configured with P+1),
directly without call, or activation of the actuator
346210 (configured with P+1 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+1)
EP door lock release (configured with P+2),
directly without call, or activation of the actuator
346210 (configured with P+2 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+2)
M = 26 Key functions described above + Professional studio
M = 46 Key functions described above + Pager
M = 86 Key functions described above + Professional studio + Pager
2524
Classe100 X16E
User and installation manual
MODE KEY SERVICE NOTES
M = 10
General intercom, it sends the call to all the
apartment devices, in systems with apartment
interface 346850, or intercom towards all the
apartment devices in systems without apartment
interface 346850;
Activation of the EP (configured with P+1) directly
without call or activation of the actuator 346210
(configured with P+1 and MOD=9)
EP door lock release (configured with P+1),
directly without call, or activation of the actuator
346210 (configured with P+1 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+1)
EP door lock release (configured with P+2),
directly without call, or activation of the actuator
346210 (configured with P+2 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+2)
M = 30 Key functions described above + Professional studio
M = 40 Key functions described above + Pager
M = 50 Key functions described above + Professional studio + Pager
M = 12
Intercom among apartments Xin systems with
apartment interface 346850
N=1
Intercom among apartments in systems with
apartment interface 346850
N=2
EP door lock release (configured with P+1),
directly without call, or activation of the actuator
346210 (configured with P+1 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+1)
EP door lock release (configured with P+2),
directly without call, or activation of the actuator
346210 (configured with P+2 and MOD=5), or
activation of door lock actuators 346230 - 346260
(configured with P+2)
M = 32 Key functions described above + Professional studio
M = 52 Key functions described above + Pager
M = 92 Key functions described above + Professional studio + Pager
26
Classe100 X16E
User and installation manual
MODE KEY SERVICE NOTES
M = 13
Intercom among apartments in systems with
apartment interface 346850
N=1
Intercom among apartments in systems with
apartment interface 346850
N=2
Intercom among apartments in systems with
apartment interface 346850
N=3
Intercom among apartments in systems with
apartment interface 346850
N=4
M = 33 Key functions described above + Professional studio
M = 53 Key functions described above + Pager
M = 93 Key functions described above + Professional studio + Pager
2726
Classe100 X16E
User and installation manual
1
1.
If necessary, during the call press the joystick to display the image sound/brightness/contrast/
colour adjustment menu (see Audio/video parameter adjustment).
CALL ORIGIN DISPLAY
Audio entrance panel
Video entrance panel Image taken by the entrance panel
Video door entry unit (intercom)
Smarthphone
The following procedure illustrates the call from the video EP
Use from the device
Functions
Answer a call
When a call is received, the display shows different information depending on the type of caller:
Note: the background and icons shown may differ from those on the device.
Call another room or apartment
(intercom)
PE or cameras direct auto-switching on
NETATMO cameras
Door lock release
Paging
28
Classe100 X16E
User and installation manual
2
B
A
2.
Touch to answer the call. The LED switches off. To end the call touch the (A) key, and to open the
Entrance Panel door lock touch the (B) key.
2928
Classe100 X16E
User and installation manual
1
A
#2
B
Call another room or apartment (intercom)
This section can be used to communicate with other video/audio Internal Units installed in your
home, or in other apartments.
The programmable key to use for calling a certain Internal Unit is set by the installer (see
Programming of the programmable keys).
Key (A) lights up to indicate that the call is active.
The display shows the ID of the Internal Unit called (B).
1. For example, touch programmable key to activate the communication with the Internal Unit
(e.g. configured as 2)
30
Classe100 X16E
User and installation manual
#2
When the Internal Unit answers, the key starts to flash; communicate with the Internal Unit, or
touch to close the call.
Note: if during the conversation a call is received from the Entrance Panel, the conversation is
interrupted in order to answer the Entrance Panel call.
3130
Classe100 X16E
User and installation manual
1
A
2
PE or cameras direct auto-switching on
Using the automatic switch on key it is possible to display the main Entrance Panel camera and, if
installed, scroll through other cameras/Entrance Panels.
Using the programmable keys it is also possible to directly display a camera or Entrance Panel.
The programmable key to use for calling a certain Entrance Panel is set by the installer (see
Programming of the programmable keys).
1. Touch to display the Entrance Panels or the cameras in your system.
2. If necessary, during the call press the joystick to display the image sound/brightness/contrast/
colour adjustment menu (see Audio/video parameter adjustment)
The (A) key flashes; if necessary, touch this key to enable audio communication.
32
Classe100 X16E
User and installation manual
4
3
A
B
3. Touch to display another Entrance Panel or camera (using the scrolling service).
When switching from one camera to the next, the (A) key lights up.
To end camera display mode wait for the switching off time to elapse or press the (B) key
4.
To display a specific Entrance Panel, touch (for example) programmable key
Note: switching from one camera to another is also possible without enabling the audio.
Note: NETATMO cameras are not included in the cycling function, and therefore will not be displayed. To
display a Netatmo camera refer to the Netatmo Cameras section
3332
Classe100 X16E
User and installation manual
1
NETATMO cameras
If your home includes NETATMO cameras, after associating them to the Home + Security App you
will be able to use them for video control directly from your Classe100 X16E with Netatmo.
If your NETATMO account is associated to several homes, each with one or more cameras, the full
home list will be displayed.
You will therefore be able to see images of your seaside home from your Classe100 X16E installed
in your main home
Note: this page appears only if the display of the NETATMO cameras has been activated in the
Home+Security app.
1. From stand-by press the joystick to activate the display.
2. Press to display the Netatmo cameras in your home.
NETATMO
2
34
Classe100 X16E
User and installation manual
3. Move the joystick up/down to select the camera that you want to display.
4. Touch to activate the desired camera, (the image is displayed for three minutes).
LIVING ROOM
3
LIVING ROOM
4
3534
Classe100 X16E
User and installation manual
5
5. Touch to end.
36
Classe100 X16E
User and installation manual
1
2
Door lock release
1.
Touch to open the main Entrance Panel door lock.
2.
To open a specific door lock, touch (for example) programmable key
.
It is possible to open the main Entrance Panel door lock, using the door lock key.
Using the programmable keys, it is also possible to open the system door locks.
The programmable key to use for opening a certain door lock is set during the configuration by
the installer (see Programming of the programmable keys).
3736
Classe100 X16E
User and installation manual
1
A
3
2
Paging
This function can be used to send voice messages using the microphone of the Classe100 X16E
through the speakers of the sound system.
This function is enabled during the configuration by the installer (see Programming of the
programmable keys)
1.
Touch to open the communication, the key (A) lights up to indicate that the call is active
2. Play the message.
3. Touch to end the call.
38
Classe100 X16E
User and installation manual
25-35 cm
40
cm
Services
The INDUCTIVE LOOP service enables the device to be used by people wearing hearing aids with
(T) selector.
Switch the acoustic device to the T position. To ensure correct magnetic coupling between the
handset and the acoustic device, we recommend a position in front of the device, at a distance of
25-35 cm.
Inductive loop (only item 344682)
Note: the presence of metal and background noise generated by electric/electronic devices (e.g.
computer) may compromise the performance and the quality of the coupling device.
With preset systems it is possible to also enjoy a range of services, such as:
Inductive loop (only item 344682)
Door status
Professional Studio (Office)
Safe door lock
3938
Classe100 X16E
User and installation manual
1
2
Door status
This service indicates through the door lock LED if the entrance door is open or closed.
This service is enabled during the configuration by the installer (see Programming of the
programmable keys).
1. If the LED flashes, the entrance door is open.
2. If the LED is off, the entrance door is closed.
Note: the service is active only if required by the system - accessory devices are required.
Note: It cannot be activated together with the Professional Studio (Office) service.
40
Classe100 X16E
User and installation manual
1
When a call is received from the Entrance Panel, this service automatically opens the associated
door lock without the need for pressing the door lock control key.
This service can be enabled during the configuration by the installer (see Programming of the
programmable keys) and activated using the specific menu (see enable/disable Professional
Studio).
1.
If this service is active, the Door Lock LED flashes.
When a call is received from the Entrance Panel, the door lock is opened automatically.
Professional Studio (Office)
4140
Classe100 X16E
User and installation manual
1
Safe door lock
When active, this service prevents the opening of the Entrance Panel door lock unless
communication with the same is active.
Therefore, the opening of the door lock is only permitted when Entrance Panel and Internal Unit
are in voice communication.
This service is enabled during the configuration by the installer (see rear view).
When this service is active, the door lock key or one of the programmable keys that activate the
door lock are disabled.
Note: the service cannot be activated together with the Professional Studio (Office) service
1.
If one of these controls is pressed, the corresponding LED flashes, but the command is not
executed.
42
Classe100 X16E
User and installation manual
+
-
Device adjustments and settings
Use of the joystick
Using the joystick it is possible to perform adjustments (Adjustments and/or Parameter
Adjustment menu during Audio/Video connection) and settings (Settings menu)
You must use the joystick on the side of the device to navigate on the menu and select the
settings.
SYMBOL ACTIONS TO BE PERFORMED SERVICE
Press Confirm/access the Adjustments
mode
> 5 sec Press and hold down for more than 5 sec Access the Settings mode
Move the joystick up (when released, it
returns to central position) Previous page/increase level
Move the joystick down (when released, it
returns to central position) Next page/decrease level
4342
Classe100 X16E
User and installation manual
From stand-by press the
joystick to activate the display
Move the joystick up/down to
select the page among:
You can download the Home
+ Security App from the
Stores.
The page disappears after the
first association with the App:
Wi-Fi adjustments and settings
Wi-Fi adjustments and settings menu
Adjust the ringtone volume.
Home_Wi-Fi
Display the NETATMO
cameras
NETATMO
Activate/deactivate the
Professional studio-Office
function.
OFF
Note: the image shows the device with all its functions enabled. The background and icons shown may
differ from those on the device.
Home + Security
44
Classe100 X16E
User and installation manual
Device info.
Wi-Fi settings page,where it
is possible to enable/disable/
reset the Wi-Fi, perform the
first association to the app
and reset the device.
Exit the menu.
4544
Classe100 X16E
User and installation manual
From stand-by press the joystick to activate the display and select the corresponding page.
Ringtone volume adjustment
1 Press the joystick to adjust
the volume.
The ringtone is played at
the set volume level.
Home_Wi-Fi
1
2 Move the joystick up/
down to select the
volume level (1 – 8).
2
2
4 Move the joystick up/
down to select another
setting or the last page to
exit.
Home_Wi-Fi
4
4
3 Press the joystick to
confirm the setting or wait
for the timeout.
3
The minimum level
corresponds to the exclusion
of the ringtone. The
corresponding LED flashes red.
46
Classe100 X16E
User and installation manual
Note: it cannot be activated together with the Safe Door Lock and the Door Status function.
From stand-by press the joystick to activate the display and select the corresponding page
When a call is received from the entrance panel, this function automatically activates the
associated door lock without the need for pressing the door lock control key.
To enable this function, Classe100 X16E must be configured as shown in the Programming of the
programmable keys.
Moreover, the function must be enabled as follows:
Activate/deactivate the professional studio-office function
A Function status
notification (ON =
enabled, OFF = disabled).
1 Press the joystick to
change mode.
OFF
1
A
2 Move the joystick up/
down to select another
setting or the last page to
exit.
2
2
ON
4746
Classe100 X16E
User and installation manual
WI-FI settings
From stand-by press the joystick to activate the display and select the corresponding page.
Note: to connect the device to the Wi-Fi network and to the app, you must first associate the Classe100
X16E to the Home + Security app.
Reset the Wi-Fi network
WI-FI RESET
Enable/disable the Wi-Fi
Network
Home_Wi-Fi
Press the joystick to select the
page of interest.
48
Classe100 X16E
User and installation manual
Note: to disconnect the Wi-Fi network from the device, the device must be reset following the
appropriate procedure.
Enable/disable the Wi-Fi Network
In this page you can display the Wi-Fi network to which the device is connected and if necessary
disable the connection.
Device reset
CLASEE 100X RESET
A Wi-Fi network name
to which the device is
connected;
1. press the joystick to
disable the Wi-Fi network.
A
Exit the menu.
Now the Wi-Fi network is no
longer active, but the device
is still authenticated to it.
OFF
Home_Wi-Fi
1
4948
Classe100 X16E
User and installation manual
Reset the Wi-Fi network
Note: if the procedure is not completed, after a few seconds the connection is restored.
In this section it is possible to change the Wi-Fi network to which the device is connected, or the
network password.
1. Press the joystick to reset
the Wi-Fi network.
3. Press the joystick to
confirm.
2. Move the joystick down
to select the confirmation
icon.
Now the device is no longer
connected to the Wi-Fi
network.
To reconnect the device to the
same network or to a new one,
you must complete the guided
procedure from the Home +
Security app in the Settings/
Set the video internal unit
Wi-Fi.
WI-FI RESET
1
3
2
50
Classe100 X16E
User and installation manual
Note: all the data concerning associated accounts and the Wi-Fi connection will be deleted.
Device reset
This page can be used to reset the device.
3. Press the joystick to
confirm.
3
2. Move the joystick down
to select the confirmation
icon.
2
1. Press the joystick to reset
the device.
CLASSE 100X RESET
1
50


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bticino Classe100 X16E - 344682 - 344782 - 344932 - 344786 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bticino Classe100 X16E - 344682 - 344782 - 344932 - 344786 in the language / languages: English as an attachment in your email.

The manual is 14.56 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info