BRULA NEO operating instructions
Display: Here, among other things, is the Screen Saver sub-menu. Here
you can choose the brightness level you wish to have for the screen saver.
If you choose several temperatures, these will be displayed at 7-second
intervals. If you pull the brightness controller all the way to the left, the display
will go dark. The screen saver switches on automatically about 2 minutes
after the most recent keystroke. The screen image reappears whenever you
touch the display unit.
Note: With water applications, it is advisable to display the temperature
at the top in the buffer. This means that you can see immediately the
level of progress of the loading of the buffer.
In addition, there is a "Cleaning the display" sub-menu. This switches off the
display for 2 minutes. During this time, it accepts no commands. This means
you can clean without altering any of the settings. For checking purposes, a
timer runs backwards and shows the remaining time.
Sound: Here the button acknowledgement sounds and the alarm sounds
can be selected. Also, the volume level can be adjusted. All sound events
can also be switched off here.
Operation auto/manual: Here you can switch from Automatic to Manual
mode. To do this, move the "auto/man" control knob to the right. Now a
position can be selected for the throttle valve and it can be sent off using the
SAVE button at the top right. To return to Automatic mode, slide the control
knob to the left again and save it.
CAUTION: Operation of the fireplace in Manual mode is at the user's
own risk! During a burnup, the air control lever must never be closed
to the point where an explosion might occur. We urgently advise that
you ONLY operate the control system IN AUTOMATIC MODE.
Language: Here, you can select the menu language of your choice.
Available at the present time: GB - DE - NL - FR - IT - ES - PL - CZ - SE
Deactivating the door: Exactly as in the display (see above), the door
detection can be deactivated for 2 minutes. This can scale down the glow
without the control system initiating a new burnup when the door is next
opened.
System information: Here you will find details about the details of the
respective versions of software used.