1883
137
Zoom out
Zoom in
Previous page
1/152
Next page
A. Appendix
129
When FIM (US-Post Net) is selected with the parameter ‘t3’ or ‘T3’
Characters ‘A’ to ‘D’ are valid and one digit of data can be printed. Upper-case and lower-case alphabet
characters can be accepted.
When Post Net (US-Post Net) is selected with the parameter ‘t4’ or ‘T4’
Numbers ‘0’ to ‘9' can be data and it must end with a check digit. ‘?’ can be used instead of the check digit.
When EAN 8, EAN 13, or UPC A is selected with the parameter ‘t5’ or ‘T5’
Ten numbers ‘0’ to ‘9’ can be accepted as bar code data. The number of characters for bar codes is limited
as follows:
EAN 8: Total 8 digits (7 digits + 1 check digit)
EAN 13: Total 13 digits (12 digits + 1 check digit)
UPC A: Total 12 digits (11 digits + 1 check digit)
A number of characters other than those stated above will cause a data error that results in the bar code
data being printed as normal print data. If the check digit is not correct, the printer decides the correct
check digit automatically so that the correct bar code data will be printed. When EAN13 is selected, adding
‘+’ and a two-digit or five-digit number after the data can create an add-on code.
When UPC-E is selected with the parameter ‘t6’ or ‘T6’:
The numbers ‘0’ to ‘9’ can be accepted as bar code data.
1
‘?’ can be used instead of a check digit.
2
Adding ‘+’ and two-digit or five-digit number after the data creates an add-on code.
When Codebar is chosen with the parameter ‘t9’ or ‘T9’
Characters ‘0’ to ‘9’, ‘-’, ‘ . ’, ‘$’, ‘/’, ‘+’, ‘ : ’ can be printed. Characters ‘A’ to ‘D’ can be printed as a start-
stop code, which can be upper case or lower case. If there is no start-stop code, errors will happen. A
check digit cannot be added and using ‘?’ causes errors.
When Code 128 Set A, Set B, or Set C is selected with the parameter ‘t12’ or ‘T12’, ‘t13’ or ‘T13’, or ‘t14’
or ‘T14’
Code 128 sets A, B and C can be individually selected. Set A shows characters Hex 00 to 5F. Set B
includes characters Hex 20 to 7F. Set C includes the pairs 00 to 99. Switching is allowed between the code
sets by sending %A, %B, or %C. FNC 1, 2, 3, and 4 are produced with %1, %2, %3, and %4. The SHIFT
code, %S, allows temporary switching (for one character only) from set A to set B and vice versa. The ‘%
character can be encoded by sending it twice.
When ISBN (EAN) is selected with the parameter ‘t130’ or ‘T130’
The same rules apply as for ‘t5’ or ‘T5’.
When ISBN (UPC-E) is selected with the parameter ‘t131’ or ‘T131’:
The same rules apply as for ‘t6’ or ‘T6’.
Eight digits
1 2
(standard format) The first character must be 0 and the data must end with a check digit.
Total eight digits =
0 plus 6 digits plus 1 check digit.
Six digits
2
The first character and the last check digit are removed from the eight digit data.
137


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brother HL-5270DN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brother HL-5270DN in the language / languages: English as an attachment in your email.

The manual is 5,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Brother HL-5270DN

Brother HL-5270DN User Manual - German - 154 pages

Brother HL-5270DN User Manual - Dutch - 152 pages

Brother HL-5270DN User Manual - French - 152 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info