644490
255
Zoom out
Zoom in
Previous page
1/262
Next page
BE-1204B-BC • BE-1206B-BC 12-7
Chapter 12 Troubleshooting
Symptom Measures
Power voltage upper or lower limit
error occurs.
Is the tap voltage in the control box (connector connection) adjusted to
the power voltage of the area where the machine is used?
If not, switch the connector connection.
Check the input voltage values in the power/voltage check test mode.
Measure the power supply voltage with the tester and compare them.
If the voltage value is significantly out of the normal range (± 5v or
more), calibrate it with the voltage calibration in the PC test mode.
When you cannot enter the test mode because this error frequently
occurs, set the voltage to a relatively high value with the machine
controller if it is E-D2 and to a relatively low value if it is E-D3 to avoid
errors. Check and calibrate the voltage in the test mode.
Check to see the connection of connector P2 of the power supply PCB
to connector P10 of the power supply PCB in the control box is proper.
Is the power supply abnormally low because a machine with a large
capacity (compressor and the like) is used?
Change the power to the other system. Use a stabilizer.
Replace the power PCB with a new one. Replace the main PCB with
a new one.
Only a certain head does not
operate.
Is the head out of action with either the head switch or the machine
controller?
Refer to the block diagram showing cable connections and check to
see that other cables are connected to the head switch PCB and the
head PCB and the head PCB properly.
Jump motor does not operate. Check to see if connection from the jump motor to connector P11 and
P12 of the head PCB is proper.
Wiper motor does not operate.
Check to see if connection from the wiper motor to connector P8 and
P9 of the head PCB is proper.
Replace the head PCB with a new one.
255


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brother BE-1206B-BC PC control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brother BE-1206B-BC PC control in the language / languages: English as an attachment in your email.

The manual is 7,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info