age the fi lter head connections and invalidate any guarantee claims. Only hoses that comply with
DVGW-W 543 may be used to connect the device.
Before assembly, note the direction of fl ow on the upper side of the fi lter head, “IN” = water inlet,
“OUT” = water outlet. Prior to installation, note installation dimensions and operating position
(Chapter 12). If no original hoses are used, the 1"–3/4"
17
adapter supplied must be used to ensure
the return valve is sealed correctly (pre- tted in the water inlet).
5 Commissioning a New Filter
5.1 Bypass Setting for Filter Systems without and with Measuring and Display Unit
Identify the local carbonate hardness in German hardness °dH (BRITA nomenclature °KH) using
the enclosed carbonate hardness test.
Check the bypass setting on the bypass screw
19
.
Note: The bypass has been set to Position 1 in the factory, and must be changed to suit the
local carbonate hardness and the application (Chapter 7).
5.2 Commissioning the Filter Systems with Measuring and Display Unit
Representation in operating mode
Local Carbonate
Hardness Set
Type/
By-Pass Proportion
Date Field: Installation or
last fi lter change date
Available residual
capacity in litres
Bar Display
Flow Symbol
Carbonate Hardness
The units of carbonate hardness can be set as required to German °dH (= display setting °KH),
English (°e = Clark) (= display setting °EH), French (°f) (= display setting °FH), American (grains
per gallon) (= display setting gpg) or international hardness values (mg/l CaCO
3
) (= display setting
mg/L).
If the setting for the type of hardness (= unit) is changed while the fi lter is operating, the values that
were set originally are converted automatically.
Bar chart
Representation of the remaining capacity using bar charts. After installation of a new fi lter system or
after a fi lter change, the symbolised fi lter cartridge is completely fi lled with 10 bars.
Bypass proportion in percentage
The by-pass proportion is defi ned as the proportion of decarbonised water in the total amount of
ltrate and is indicated as a percentage.
Flow symbol
When water is removed via the fi lter system, a graphic wave is shown on the display.
Available remaining capacity of the fi lter cartridge
The remaining capacity of the fi lter cartridge is shown in litres or in US gallons, depending on which
has been selected.
When water is removed, it counts backwards in 1 litre or 1 US gallon stages. If the cartridge is
already exhausted, the capacity is indicated as being negative by fl ashing.
28


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brita PURITY Quell ST at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brita PURITY Quell ST in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 4,47 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info