SUBSTANCE REDUCTION
The above listed Water Filter Systems have been tested and certifi ed under NSF/ANSI 42 for reduc-
tion of chlorine, taste and odour. The performance of this product has been verifi ed and substanti-
ated as the test data summarised below indicates. These substances may not be in your water.
Test Data for Purity C 50 Quell ST
Substance
Guidelines
Average Infl uent
Concentration
Maximum Ef uent
Concentration
Minimum Percent
Removal
Average Ef uent
Concentration
Average Percent
Removal
Chlorine
NSF/ANSI 42 2.11 mg/l 0.40 mg/l 81.0 % 0.24 mg/l 88.7 %
*Test Data for Purity C 150 Quell ST
Substance
Guidelines
Average Infl uent
Concentration
Maximum Ef uent
Concentration
Minimum Percent
Removal
Average Ef uent
Concentration
Average Percent
Removal
Chlorine
NSF/ANSI 42 2.11 mg/l 0.40 mg/l 81.0 % 0.24 mg/l 88.7 %
*Test Data for Purity C 300 Quell ST
Substance
Guidelines
Average Infl uent
Concentration
Maximum Ef uent
Concentration
Minimum Percent
Removal
Average Ef uent
Concentration
Average Percent
Removal
Chlorine
NSF/ANSI 42 2.11 mg/l 0.40 mg/l 81.0 % 0.24 mg/l 88.7 %
Test Data for Purity C 500 Quell ST
Substance
Guidelines
Average Infl uent
Concentration
Maximum Ef uent
Concentration
Minimum Percent
Removal
Average Ef uent
Concentration
Average Percent
Removal
Chlorine
NSF/ANSI 42 2.03 mg/l 0.62 mg/l 69.0 % 0.40 mg/l 80.1 %
Test Data for Purity C 1000 AC
Substance
Guidelines
Average Infl uent
Concentration
Maximum Ef uent
Concentration
Minimum Percent
Removal
Average Ef uent
Concentration
Average Percent
Removal
Chlorine
NSF/ANSI 42 2.1 mg/L 0.05 mg/L 97.4 % 0.05 mg/L 97.6 %
*Values calculated on basis of the C50
Testing Conditions:
Flow Rate: 0.25 GPM pH: 7.5+/0.5
Pressure: 60+/– 3 psgi Temperature: 20+/C
Refer to your Instruction Guide for more specifi c product and warranty information and to avoid
contamination from improper handling and installation. Performance will vary based on local water
conditions. The substances reduced by this product are not necessarily in your water.
Buyer’s Signature Date Seller’s Signature Date
This appliance meets the domestic water treatment appliance Standards AS/NZS 3497 and
AS/NZS 4348 for the following water treatment process:
Class Treatment type Function Pass
I Microbiological Status
Bacteriostatic
Will stop bacteria increasing N/A
II Microbiological Treatment
Bacteria removal
Virus removal
Protozoa removal
Will remove or inactivate bacteria
Will remove or inactivate virus
Will remove or inactivate Crypto-sporidium and Giardia
N/A
N/A
N/A
III Turbidity and particulate reduction
Reduces cloudiness N/A
IV Taste and odour reduction
Reduces tastes and odours
V Chemical treatment
Decreases chlorine
LEGEND:
= pass
N/A = Not Applicable
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brita PURITY C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brita PURITY C in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 3,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info