2. Installeren
Installatievoorschriften Renovent HR 400 juni 2003
-
9
-
2.9 Temperatuurinstellingen regelprint bypass (alleen indien bypass is gemonteerd)
In het toestel met een bypass is een regelprint geplaatst welke het openen en sluiten van de bypass
automatisch regelt.
De bypass opent wanneer: - de buitentemperatuur lager is dan de binnentemperatuur (led I = aan) en
- de buitentemperatuur hoger is dan 15°C (led J = aan) en
- de binnentemperatuur hoger is dan 20°C. (led H = aan)
De bypass sluit wanneer: - de buitentemperatuur hoger is dan de binnentemperatuur of
- de buitentemperatuur lager is dan 15°C of
- de binnentemperatuur lager is dan 20°C.
A = Voedingssteker 230 V regelprint bypass
B = Voedingssteker 230 V bypassklep
C = Aansluiting binnentemperatuurvoeler
D = Aansluiting buitentemperatuurvoeler
E = Groene led aan (bypassklep schakelt uit)
F = Gele led aan (bypassklep schakelt in)
G = Rode led aan (bypassklep actief)
H = Gele led (binnentemperatuur > 20°C; instelbaar met P1)
I = Gele led (verschil buiten- en binnentemperatuur >
ingestelde waarde; instelbaar met P2)
J = Gele led (buitentemperatuur > 15°C; instelbaar met P3)
K = Zekering 2 A(T)
L = Potmeter P1 (instelling binnentemperatuur tussen 18
en 24°C)
M = Potmeter P2 (instelling differentie tussen 1 en 3°C)
N = Potmeter P3 (Instelling buitentemperatuur tussen 10 en
15°C)
5272
Figuur 10: Vooraanzicht regelprint bypass.
Wanneer de led's H, I en J aan zijn dan is de bypassklep open.
De binnen- en buitentemperatuur wordt gemeten door middel van twee temperatuurvoelers welke in het
toestel zijn geplaatst.
De temperatuurvoeler welke is aangesloten op aansluiting D van de bypassprint meet de buiten-
temperatuur; de temperatuurvoeler aangesloten op aansluiting C van de bypassprint meet de binnen-
temperatuur.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brink RENOVENT HR 400 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brink RENOVENT HR 400 in the language / languages: Dutch as an attachment in your email.

The manual is 0,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info