42 Renovent Excellent 300/ 400 Rev G April 2013
67$3
NR.
OMSCHRIJVING
FABRIEKS-
INSTELLING
INSTELBEREIK 67$3
',63/$<7(.67
6<0%2/(1
01
Luchtdebiet Excellent 300 : stand
50 m
3
/h 0 m
3
/h of 50 m
3
/h
Luchtdebiet Excellent 400 : stand
50 m
3
/h 0 m
3
/h of 50 m
3
/h
02 Luchtdebiet Excellent 300 : stand 1 100 m
3
/h 50 m
3
/h t/m 300 m
3
/h
5 m
3
/h
Luchtdebiet Excellent 400 : stand 1 100 m
3
/h 50 m
3
/h t/m 400 m
3
/h
03 Luchtdebiet Excellent 300 : stand 2 150 m
3
/h 50 m
3
/h t/m 300 m
3
/h
5 m
3
/h
Luchtdebiet Excellent 400 : stand 2 200 m
3
/h 50 m
3
/h t/m 400 m
3
/h
04 Luchtdebiet Excellent 300 : stand 3 225 m
3
/h 50 m
3
/h t/m 300 m
3
/h
5 m
3
/h
Luchtdebiet Excellent 400 : stand 3 300 m
3
/h 50 m
3
/h t/m 400 m
3
/h
05 Bypasstemperatuur 22,0 °C 15,0 °C - 35,0 °C 0,5 °C
BYPASS
06 Bypass hysterese 2,0 °C 0,0 °C - 5,0 °C 0,5 °C
BY HYS
07 Werking bypassklep 0
0 (= Automatisch werken)
1 (= Bypassklep gesloten)
2 (= Bypassklep open)
BYPASS
08 Communicatie eBUS
Ot ( = Opentherm)
eBUS
OT/BUS
09 Bus adres 0 0 - 9 (0 = Master) BUSADR
10 CV + WTW OFF
OFF (= CV+WTW uitgeschakeld)
ON (= CV+WTW ingeschakeld)
CV+WTW
11 Onbalans toelaatbaar ON
OFF (= debiet toe- afvoer gelijk)
ON (= onbalans toelaatbaar)
12 Vaste onbalans 0 m
3
/h -100 m
3
/h t/m 100 m
3
/h 1 m
3
/h
67$3
NR.
OMSCHRIJVING
FABRIEKS-
,167(/3/86
INSTELBEREIK 67$3
13 Verwarmer 0
0 (= uit)
1 (= voorverwarmer)
2 (= naverwarmer)
HEATER
14 Temperatuur naverwarmer 21,0 °C 15,0 °C t/m 30,0 °C 0,5 °C
HEATER
15 Selectie ingang 1 0
0 (= maakcontact)
1 (= 0 - 10V ingang)
2 (= verbreekcontact)
3 (= schakeluitgang 1/ bypas open ¼ 12V;
bypass gesloten¼ 0V)
4 (= schakeluitgang 1/ bypas open ¼ 0V;
bypass gesloten¼ 12V)
V1
16 Minimale spanning ingang 1 0,0 V 0 Volt - 10 Volt 0,5 V V1 MIN
17 Maximale spanning ingang 1 10,0 V 0 Volt - 10 Volt 0,5 V V1 MAX
18
Voorwaarden
schakelingang 1
0
0 (= Uit)
1 (= Aan)
2 (= Aan wanneer aan voorwaarden
bypass open voldaan)
3 (= Bypass aansturing)
4 (= Slaapkamerklep)
CN1
19
Toevoerventilator mode
schakelingang 1
5
0 (= Toevoerventilator uit)
1 (= Absoluut min.debiet 50m
3
/h)
2 (= Debiet stand 1)
3 (= Debiet stand 2)
4 (= Debiet stand 3)
5 (= Standenschakelaar /perilex)
6 (= Maximale debiet)
7 (= Geen aansturing toevoerventilator)
CN1
Hoofdstuk 13 Instelwaarden
46


Need help? Post your question in this forum.

Forumrules
1

Forum

brink-renovent-excellent-300

Reset search

  • Trying to set flow at 165 cubic meters " keeps going back to 50 ? Submitted on 27-1-2022 at 17:41

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brink Renovent Excellent 300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brink Renovent Excellent 300 in the language / languages: Dutch as an attachment in your email.

The manual is 2,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info