10 Renovent Excellent 180
The Renovent Excellent 180 is also available as “Plus” version.
This version is equipped with a different control board with 2
additional connectors (X14 & X15) with more connection opti-
ons for various applications.
The “Plus” version has a 9-pole connector which is connected
to X15 from the control board. This 9-pole connector is acces-
sible from the top of the Renovent Excellent 180.
The 2-pole connector X14 is accessible after sliding the control
board to the front from the appliance (see §9.2 item 1 - 5). An
additional gland is available at the top of the appliance in “Plus”
version>. That makes it possible to feed a 230 V cable, which
may be connected to connector X14, to outside the appliance.
Always use a gland with strain reliever.
See § 11.1 for more information on the connection possibilities
of connectors X14 and X15.
Chapter 4 Operation
4.3 Frost safety
To prevent freezing of the heat exchanger at extremely low
outdoor temperatures, the Renovent Excellent 180 features
frost control. Temperature sensors measure the temperatures
across the heat exchanger and, if an optional preheater is in-
stalled, it will be switched on when required.
That guarantees a proper ventilation balance, also at very low
outdoor temperatures. If, with switched on preheater, the ex-
changer temperature still starts to drop below zero, stepless
unbalance is created in the appliance.
4.3 Renovent Excellent Plus version
4.1 Description
The appliance comes plug and play and operates fully auto-
matically. The exhausted indoor air heats up the fresh, clean
outdoor air. That saves energy and fresh air is sent to the re-
quired rooms.
The control system has four ventilation modes.
Dependent on the connected multiple switch, 3 or 4 ventilation
PRGHVFDQEHXVHG7KHDLUÀRZUDWHFDQVHSDUDWHO\EHDG-
MXVWHGIRUHDFKYHQWLODWLRQPRGH7KHFRQVWDQWYROXPHFRQWURO
V\VWHPHQVXUHVWKDWWKHDLUÀRZUDWHRIWKHVXSSO\DQGH[KDXVW
fans is realised independent of the duct pressure.
4.2 Bypass function preconditions
Because of its compact design, the appliance is not equipped
with a bypass diffuser but it uses bypass functionality. Bypass
functionality means that the supply fan is switched off when the
E\SDVVSUHFRQGLWLRQVDUH VDWLV¿HG7KHQ WKHUH LVRQO\D PH-
FKDQLFDOH[KDXVWDLUÀRZWKURXJKWKHKHDWH[FKDQJHUVRXQ-
der these conditions -undesired- heat recovery does not occur.
Optimum performance of this system requires natural supply. It
is assumed that at very high indoor temperatures the user will
automatically open the windows for reasons of comfort. The
RSHUDWLRQRIWKHE\SDVV IXQFWLRQFDQEH DGMXVWHG XVLQJ VWHS
number 5, step numbers 6 and step number 7 in the settings
menu (see chapter 13).
Bypass function preconditions
Bypass function active - The outdoor temperature is higher than 10°C and
- the outdoor temperature is lower than the indoor temperature in the dwelling and
- the temperature in the dwelling is higher than the temperature set at step no. 5 in the set-
tings menu (set a standard at 22°C)
Bypass function not active - The outdoor temperature is lower than 10°C or
- the outdoor temperature is higher than de indoor temperature in the dwelling or
- the temperature from the dwelling is higher than the temperature set at step no. 5 in the set-
tings menu minus the preset temperature at hysteresis (step no. 6); the factory setting for
this temperature is 20°C (22.0°C minus 2.0°C).
Feed-through op-
tion for 230V cable
from X14.
9-pole connector
54


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Brink Renovent Excellent 180 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Brink Renovent Excellent 180 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 12,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info