611625
10
Zoom out
Zoom in
Previous page
1/44
Next page
Looking at or near the Sun will cause instant and irreversible damage to your eye!
10
9.
Attach viewfinder bracket
(Abb. 9b). Locate the viewfinder bracket screws
(15, Fig. 1b and Fig. 9a) and remove the nuts from the screws. Slide
the holes in the viewfinder bracket over the viewfinder bracket screws.
Replace the nuts and tighten to a firm feel only.
9a. Attach viewfinder tube:. Back off the viewfinder collimation screws (5, 
Fig. 1b) and slide the viewfinder tube into the bracket. Orient the view-
finder eyepiece as depicted in Fig. 1b. Tighten the collimation screws to
a firm feel. See Aligning the viewfinder, page 14.
10. Insert the eyepiece: NT models (Fig. 10a): Lift to remove the dust cap
from the eyepiece holder on the focuser assembly. Set the dust cap
aside in a safe place and replace it when you have finished observing
to protect the eyepiece assembly. Back off the eyepiece thumbscrews 
(1, Fig. 1a) and insert the supplied 25mm eyepiece (3, Fig. 1a) into the
the eyepiece holder. Tighten the holder thumbscrews to a firm feel to
secure the eyepiece. AR models (Abb. 10b): Lift to remove the dust cap
from the eyepiece holder on the focuser assembly. Set the dust cap
aside in a safe place and replace it when you have finished observing
to protect the  eyepiece assembly. Back off the eyepiece thumbscrews 
(1, Fig. 1b) and slide the diagonal prism into the holder and tighten the
thumbscrews to a firm feel only. Insert the supplied 25mm eyepiece (3,
Fig. 1b) into the the diagonal prism. Tighten the prism‘s thumbscrews to
a firm feel to secure the eyepiece.
11. Adjust the height of the tripod: Adjust the height of the tripod by
loosening the tripod lock knobs (Fig. 11). Extend the sliding inner
section of each tripod leg to the desired length; then tighten each knob.
Adjust the tripod to a height that is comfortable for viewing.
13.  The 2” focusers of the Messier Series  from AR-102 or NT-130 on have 
a built in extension tube. Depending on the accessories used, or when
using a camera, it might not be possible to reach the focus. Focus tra-
vel to the inside might not be sufficient in the standard configuration.
To reach focus, unscrew the eyepiece holder, then the following 25mm
extension tube. Screw the eyepiece holder back in place.
Fig. 10b: Insert eyepiece into
diagonal prism and tighten
thumbscrews.
Eyepiece
Holder
Thumbscrews
Diagonal
prism
Viewfinder
AR
Fig. 10a: Insert eyepiece intor holder
and tighten thumbscrews.
Eyepiece
Holder
Thumbscrew
NT
Viewfinder
Fig. 11: Adjust the tripod height
using the leg lock knob.
Leg lock knob
Fig. 9b: The finder scope assem-
bly has a dovetail bracket, that
fits the holder that is mounted on
the optical tube.
as s e m b l I n G ex o s 1
* Optional accessory for Exos 2
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bresser AR-152S-L at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bresser AR-152S-L in the language / languages: English as an attachment in your email.

The manual is 1,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info