784785
15
Zoom out
Zoom in
Previous page
1/28
Next page
15 / 28
-800 ~ 800hpa / -23.62 ~ 23.62inHg / -601.5 ~ 601.5mmH g
Setting Range:
SETUP ADVANCED
Language: English
Temperature oC
Outdoor
Indoor
CH 1
CH 2
CH 3
CH 4
CH 5
CH 6
CH 7
Humidity %
Relative Pressure Offset:
Absolute Pressure Offset:
hpa
Range: -20 ~ 20
(Default: 0)
Current offset: 10Current offset: -9
Current offset: -5Current offset: 2
Current offset: -2Current offset: 3
Current offset: -2Current offset: 1.2
Current offset: -5Current offset: -0. 2
Current offset: -3Current offset: -20. 1
Current offset: -10Current offset: 11.5
Current offset: -3
Current offset: -3
(Default: 0)
Current offset: 10
(Default: 0)
Current offset: 0.2
Current offset: -5Current offset: 1
Pressure
Range: -20.0 ~ 20.0 oC
-36.0 ~ 36.0 oF (Default: 0.0)
**UV gain: Range: 0.01 ~ 10(Default: 1.00)
Current gain: 1.1
** Depends on outdoor sensor type
Wind speed gain:
**Wind direction:
Rain gain: Range: 0.5 ~ 1.5(Default: 1.00 )
Range: -10 ~ 10(Default: 0 o)
Range: 0.5 ~ 1.5(Default: 1.00 )
Current gain: 0.8 5
Current offset: 2o
Current gain: 0.7 5
Function firmware version: 1.00
WiFi firmware version: 1.00
2
36
7
8
1
4
11
9
10
5
1 Sélectionnez "SETUP" pour entrer dans le
menu des paramètres
2 Sélectionner l'unité
3 Étalonnage de la température intérieure/
extérieure et canal 1-7
4 Etalonnage de pression
5 Sélectionnez 'ADVANCED' pour accéder
au menu de réglage des paramètres
avancés
6 Calibrage de l'humidité
7 Sélectionner l'unité 8 Entrez une valeur de compensation pour
compenser la valeur de pression mesurée
9 Calibrage pluie 10 Calibrage du vent
11 Dernier firmware
CALIBRAGE
1. L'utilisateur peut entrer ou modifier les valeurs de décalage et de gain pour différents paramètres
de mesure tandis que les valeurs actuelles de décalage et de gain sont affichées à côté des cases
correspondantes.
2. Une fois terminé, appuyez [Apply] sur la page SETUP.
La valeur actuelle de l'offset affichera la valeur précédente que vous avez entrée, si vous voulez chan-
ger, entrez simplement la nouvelle valeur dans le blanc, la nouvelle valeur sera valide une fois que
vous appuyez sur l'icône [Apply] dans la page SETUP.
REMARQUE :
L'étalonnage de la plupart des paramètres n'est pas nécessaire, à l'exception de la pression relative,
qui doit être étalonnée au niveau de la mer pour tenir compte des effets de l'altitude.
20 Réglage automatique de l'heure
Une fois l'alimentation électrique et la connexion WIFI établies, les informations relatives à l'heure et à
la date sont automatiquement transmises par le serveur de temps Internet.
Si le signal radio est reçu correctement, la date et l'heure sont automatiquement réglées et l'icône du
signal radio s'allume.
Si les informations relatives à l'heure et à la date n'ont pas été reçues ou ne l'ont pas été correcte-
ment, procédez comme suit :
1. Dans les pays/régions dont le fuseau horaire diffère de l'heure mondiale coordonnée UTC, le fu-
seau horaire doit être réglé manuellement (voir le chapitre "Réglage du fuseau horaire") afin d'affi-
cher l'heure correcte.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bresser 7802581 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bresser 7802581 in the language / languages: French as an attachment in your email.

The manual is 2.63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bresser 7802581

Bresser 7802581 User Manual - English, German - 48 pages

Bresser 7802581 User Manual - Dutch - 28 pages

Bresser 7802581 User Manual - Italian - 28 pages

Bresser 7802581 User Manual - Spanish - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info