8 Battery level indicator
1. When the batteries in the base station or in the remote sensor reach the low charge level, the cor-
responding battery level indicator appears on the display.
2. When replacing a set of batteries, always also remove the batteries from the other part of the
device and reinsert the batteries in the intended order (see chapter "Setting up power supply").
Replace the batteries in the relevant part of the device with a completely new set with full capacity.
This ensures that the connection between the devices is reestablished correctly.
9 Automatic time setting
After the power supply was established, the clock will automatically search for the radio signal. This
will take approximately 3 to 8 minutes to finish this process.
If the radio signal is received correctly, the date and time will be set automatically and the radio control
signal icon turns on.
If the clock fails to receive the time signal, go ahead with the following steps:
1. Press °C/°F button on the base station for approx. 3 seconds to initate RC signal reception again.
2. If the device is still not receiving the signal, the time must be set manually.
Read the detailed manual for more information about manual time and alarm setting (see download in-
formation on page 2).
10 Manual time setting and other user defined
settings
1. In normal display mode, press MODE/SET button for approx. 3 seconds to switch to settings
mode.
2. Digits to be set are flashing.
3. Press DOWN/RAIN HISTORY button or UP/RCC/ALARM button to change the value.
4. Press the MODE/SET button to confirm the setting and move to the next setting.
5. Settings order: 12/24 hours mode > RCC on/off > time zone (-12 to +12 hours) > hours > minutes
> seconds > year > month > day > language > temperature unit > barometric pressure unit > wind
speed unit > precipitation unit > wind direction
6. Finally press MODE/SET button to save the settings and exit settings mode.
11 Alarm settings
1. In normal display mode, press the TIME button several times to display the Alarm time AL1 or
AL2.
2. Press ALARM button for approx. 3 seconds to enter the alarm time setting mode.
3. Digits to be set are flashing.
4. Press CH/UP or 12/24/DOWN button to change the value.
5. Press ALARM button to confirm and continue to the next setting.
6. Settings order: hours > minutes > ice alert on/off
NOTICE!If ice alert is enabled (on), the alarm will sound 30 seconds before the set alarm time if
the temperature is -3° or below.
7. Finally press the ALARM button to save the settings and exit the setting mode. Alarm will be activ-
ated automatically. The symbol will be displayed.
8. In normal display mode, press the ALARM button several times to enable alarm time AL1, AL2 or
both. If the alarm is enabled, the corresponding symbol will be displayed ( 1, 2 or 1 2).
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bresser 7060200 - TemeoTrend FSX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bresser 7060200 - TemeoTrend FSX in the language / languages: English as an attachment in your email.

The manual is 2,89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bresser 7060200 - TemeoTrend FSX

Bresser 7060200 - TemeoTrend FSX User Manual - German - 16 pages

Bresser 7060200 - TemeoTrend FSX User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info