784615
17
Zoom out
Zoom in
Previous page
1/88
Next page
17
EN
SET LCD DISPLAY CONTRAST
In normal mode, press [ / CAL ] key to adjust LCD contrast for best viewing on table stand
or wall mounted.
MAINTENANCE
BATTERY REPLACEMENT
When low battery indicator “ ” is displayed in CH section of the LCD display, it indicates that
the current channel sensor battery power give wireless sensor shown is low respectively. Please
replace with new batteries.
TROUBLESHOOT
Problems Solution
Indoor wireless
sensor is intermittent
or no connection
1. Make sure the sensor is within the transmission range
2. Make sure the channel displayed match to the channel selection
on sensor
3. If it still not work, reset the sensor and resynchronize with console.
No WI-FI connection 1. Check for WI-FI symbol on the display, it should be alway on.
2. Make sure you connect to 2.4G band but not 5G band of your WI-
FI router.
Temperature or
humidity not accurate
1. Do not place your console or sensor close to the heat source
2. If the sensor still not accurate adjust the value in calibration mode.
SPECIFICATIONS
CONSOLE
General Specication
Dimensions (W x H x D) 130 x 112 x 27.5mm (5.1 x 4.4 x 1.1 in)
Weight 220g (with batteries)
Main power DC 5V, 1A adaptor
Backup battery CR2032
Operating temperature range -5˚C ~ 50˚C
Operating Humidity range 10~90% RH
Support sensors - 1 Wireless Thermo-hygro sensors (included)
- Support Up to 7 Wireless Thermo-hygro sensors (optional)
RF frequency 868Mhz (EU or UK version)
Time Related Function Specication
Time display HH: MM
Hour format 12hr AM / PM or 24 hr
Date display DD / MM or MM / DD
Time synchronize method Through the server to get the local time of the console location
Weekday languages EN / DE / FR / ES / IT / NL / RU
In Temperature
Temperature unit °C and °F
Accuracy <0°C or >40°C ± 2°C (<32°F or >104°F ± 3.6°F)
0~40°C ±1°C (32~104°F ± 1.8°F)
Resolution °C / °F (1 decimal place)
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bresser 7006300 - Tuya Smart at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bresser 7006300 - Tuya Smart in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 6.53 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info