729972
13
Zoom out
Zoom in
Previous page
1/20
Next page
13
41. Barometer reading
42. Barometer measurement unit (hPa / inHg / mmHg)
43. Alarm on
Rainfall (Fig. 15)
44. Time range record indicator
45. HI Alert and alarm on
46. Current rainfall rate
47. Rainfall unit (in / mm)
Multifunctional histogram (Fig. 16)
48. Histogram variable
49. Histogram
50. Hourly records indicator
BEFORE YOU START
IMPORTANT!
1. Insert batteries for the main unit before doing so for the 6 in 1 outdoor
sensor.
2. Place the main unit as close as possible to the remote unit.
3. Position the remote unit and main unit within the effective transmis-
sion range.
When changing batteries always change batteries in the main unit as well
as all remote units and replace them in the correct order, so the remote
connection can be re-established. If batteries are exchanged in only one
of the devices (i.e. the remote sensor) the signal can’t be received or
can’t be received correctly.
Note, that the effective range is vastly affected by building materials and
position of the main and remote units. Due to external inuences (var-
ious RC devices and other sources of interference), the maximum dis-
tance can be greatly reduced. In such cases we suggest to position the
main unit and the remote sensor at other places. Sometimes all it takes
is a relocation of one of these components of a few inches!
POWER SUPPLY
Main unit (Fig. 19)
1. Plug the DC power adaptor (D) into the DC jack (25)
2. Press RESET key to re-start the main unit
3. After reset, all LCD segments will show on the display for a short mo-
ment before the unit enters the AP (access point) setup mode and the
LED lights green.
Insert backup batteries (optional)
1. Open the battery compartment door.
2. Install 3 batteries (AAA size 1.5V) strictly according to the polarities
shown.
3. Reinsert the battery compartment door.
The Main unit LED indicator can show the following status:
Status LED status
AP (access point) mode for setup ash green
light
Connected to Wi-Fi router blue light
Search the Wi-Fi router / Connection failed ash blue
light
Firmware update ash red light
Manual sensor pairing mode by pressing the [Wi-Fi /
Sensor] key
ash cyan
light
Refresh the upload data and sync internet time by
pressing the [Refresh] key
ash purple
Indoor sensor (Fig. 3)
1. Open the battery compartment door.
2. Install 2 batteries (AA size 1.5V) strictly according to the polarities
shown.
3. Reinsert the battery compartment door.
NOTE!
1. If you need to re-assign the sensor channel, rstly slide the channel
slide switch to the new channel that you want, then press the [SEN-
SOR] button on the main unit and then press the [RESET] button on the
sensor to pair the sensor with the main unit again.
2. Avoid placing the sensors in direct sunlight, rain or snow.
3. To avoid the sensor's and main unit pairing failure during new setup,
please power up the sensor's rst, and then press the [RESET] button
on the main unit (not on the sensor's).
6-in-1 Multi Outdoor sensor (Fig. 20)
1. Open the battery compartment door.
2. Install 3 batteries (AA size 1.5V) strictly according to the polarities
shown.
3. Reinsert the battery compartment door.
NOTE!
The LED will begin ashing every 12 seconds.
Low battery warning
When it is time to replace the batteries, the respective low battery indi-
cator
will be shown near to the Indoor temperature and humidity
display (batteries for main unit) or near to the Outdoor temperature and
humidity (batteries for remote sensor).
INSTALLATION
Indoor sensor
Use the mounting hole on the back of the sensor to install it on the wall
using a screw. You can also place the sensor directly to e.g. a table.
6-in-1 Multi Outdoor sensor (Fig. 17-18)
Install the wireless 6-in-1 Multi Outdoor sensor in an open location with
no obstructions above and around the sensor for accurate rain and wind
measurement. Install the sensor with the smaller end facing the North to
properly orient the wind direction vane.
Secure the mounting stand and bracket (included) to a post or pole, and
allow minimum 1.5m off the ground.
Fig. 17: Mounting on pole (Pole Diameter 50.8 mm (approx. 2“)).
Fig. 20: Circular level.
Mounting guidelines:
1. Install the wireless 6-in-1 sensor at least 1.5m off the ground for better
and more accurate wind measurements.
2. Choose an open area within 150 meters from the LCD display main
Unit.
3. Install the wireless 6-in-1 sensor as level as possible to achieve accu-
rate rain and wind measurements. A circular level device is provided to
ensure a level installation.
4. Mount the wireless 6-in-1 sensor with the wind meter end pointing to
the North to correctly orient direction of the wind vane.
Step 1:
Plug the stainless steel moun-
ting pole into the sensor's
mounting hole and tighten the
screws.
Screws
Step 2:
Fasten the stainless steel
tube on your x pole with 2
U-bolt, pole mounting clamps
and nuts.
U-bolt
Mounting
clamp
DE
EN
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bresser 7002540 PROFI W-LAN WETTER CENTER at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bresser 7002540 PROFI W-LAN WETTER CENTER in the language / languages: English, German as an attachment in your email.

The manual is 5,18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bresser 7002540 PROFI W-LAN WETTER CENTER

Bresser 7002540 PROFI W-LAN WETTER CENTER User Manual - French - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info