517806
15
Zoom out
Zoom in
Previous page
1/20
Next page
TANK DRAIN DELAY
This parameter changes the time
before the tank is emptied of
water, after the cooler has been
turned off. The 5 options available
are:
0 = 4 hours
1 = 1 day
2 = 2 days
3 = 3 days (default)
4 = 4 days.
To change the tank drain delay
use the following sequence:
(1)......With the wall control turned
OFF, hold down the
button. While holding down
this button press the
button. The current setting
and 3 central fan speed
bars will be displayed.
(2)......Press the or
button to scroll through the
available settings.
(3)......When the desired setting is
displayed, press the
button to store the new
setting.
CHANGING THE DEFAULT
PARAMETER SETTINGS
SALINITY CONTROL METHOD
SELECTOR
The following operating parameters
can be adjusted using the wall control
but only if a drain valve has been
fitted to your cooler.
This parameter controls the following
2 options. Value 0 uses the intelligent
WaterManager which measures and
controls the waters salinity level.
Value 1 drains the tank every 65
minutes when the cooler is ON. Value
0 is the preset and preferred setting.
To change the salinity control setting
use the following sequence:
(1)......With the wall control turned
OFF, hold down the
button. Continue to hold this
button down and press the
button. The current
setting and the 3 right most
fan speed bars will be
displayed.
(2)......Press the or
button to scroll through the
various setting options
discussed previously.
(3)......When the desired setting is
displayed, press the
button to store the new setting.
®
®
14
Evaporative Cooler
Your cooler is fitted with one of
two water management systems
designed to control the water
salinity and optimise the life of
the pads in your cooler.
If fitted, the bleed system,
pictured on page 16, will
constantly drain small amounts of
water during the operation of the
cooler. This allows fresh water to
be added diluting any minerals
and salts accumulated.
The bleed rate for your cooler will
depend on local operating
conditions and will be set by the
installer.
If your cooler has been installed
with a drain valve it is
accompanied by the
WaterManager salinity probes.
When the tank’s water salinity
level reaches a preset level the
WaterManager will open the
drain valve and release about 6
to 8 litres. Fresh water will then
be added diluting any minerals or
salts accumulated. The Water
Manager will continue to
monitor and drain water as
required.
BLEED SYSTEM
DRAIN VALVE
®
®
®
Alternatively, the cooler can be
set to drain 6 to 8 litres of water
at a preset period of pump
operating time. This can be set
by changing the salinity control
method selector if using the wall
control, or DIP switch F if using
the remote control.
NOTE: When the coolers tank is
empty and the cooler is turned on
again, the fan operation will be delayed
as the tank is refilled and the pads are
saturated.
If the power in your home goes off for
less than 5 seconds the cooler will
retain its current settings. That is, it will
stop for the time the power is off but
resume operation when the power
comes back on again.
If the power goes off for more than 5
seconds the cooler will automatically
turn itself off. That is, once the power
comes back on the cooler will not
resume operation. You will have to turn
the cooler back on using the wall
control or remote control.
POWER OUTAGES
SEELEY INTERNATIONAL OWNER’S MANUAL 15
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Breezair EX series at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Breezair EX series in the language / languages: English as an attachment in your email.

The manual is 0,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info