545943
7
Zoom out
Zoom in
Previous page
1/12
Next page
GB
ECopyright Bravilor Bonamat B.V.
V
version 1.0
Installation
D The maximum acceptable ambient temperature with which a good operation can be guaranteed is 40°C.
D Never install the machine in an environment where the temperature can drop below 0°C.
D Do not turn over the machine, move it upright.
D Never install the machine in places where water is sprayed or sprinkled.
D Never install the machine in front of entrances, exits or passageways intended for emergency
services.
D Place the machine on a sufficiently solid, flat surface close to a water connection, water discharge
and an earthed electrical power outlet.
D Connect the machine to the electrical supply in such a way that the power can easily be
disconnected.
D Machines hard wired into mains electricity supply we advise to use an Earth Leakage Circuit
Breaker (ELCB) of the appropriate rating (max. 30 mA).
D Leave sufficient space at the back and front of the machine for maintenance and repair purposes.
D The machine should be connected to the electricity mains in such a way that all phases and the zero
can easily be disconnected. The minimum distance between the contacts and the disconnected
position should be at least 3 mm.
D Connect the machine to a readily accessible, manually operated water tap, so that the water supply
can easily be turned off.
D Always observe local rules and standards when installing this machine.
Use
D Inspect the machine before use and check for damages.
D Protect the machine against water and moisture. Do not wet the machine by spraying and never
submerge the machine in water.
D Keep the operating controls free from dirt and grease.
D Note that during use some parts of the machine become very hot.
D Disconnect the electricity grid and the water supply when the machine will not be used for a longer
period. Clean the machine following the instructions. Discharge the water.
D Should the internal water ways of the machine become frozen, disconnect from the mains, turn off
the water supply and disconnect and place the machine in a warm environment until the water ways
have defrosted. Inspect and test machine for water leakage.
Maintenance and repairing failures
D Repair and maintenance activities not included in this document must always be carried out by
service mechanics.
D If the mains lead is visibly damaged, it has to be replaced by a qualified service technician.
D Observe the given maintenance intervals. Overdue maintenance can lead to high repair costs and
may cause guarantee claims to become invalid.
D Do not carry out any maintenance activities concerning the machine before having it protected
against unintentional coming into operation. In such cases disconnect the electricity grid.
D Never leave the machine during maintenance activities.
D For cleaning the machine only use the cleansing agent and descaler recommended by the
manufacturer.
D Always wear suitable facial protection and gloves while working with cleansing and descaling
materials. Wash your hands after using these materials.
D Prevent damage of the machine caused by spilled descaler solution. Remove spilled solution as
quickly as possible and follow the previously mentioned safety instructions.
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bravilor Bonamat RLX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bravilor Bonamat RLX in the language / languages: English as an attachment in your email.

The manual is 0,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bravilor Bonamat RLX

Bravilor Bonamat RLX Additional guide - English - 6 pages

Bravilor Bonamat RLX User Manual - English - 8 pages

Bravilor Bonamat RLX Additional guide - German - 8 pages

Bravilor Bonamat RLX User Manual - German - 6 pages

Bravilor Bonamat RLX User Manual - German - 12 pages

Bravilor Bonamat RLX Additional guide - Dutch - 6 pages

Bravilor Bonamat RLX User Manual - Dutch - 8 pages

Bravilor Bonamat RLX User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info