Error Description Potential cause and remedy
Blood pressure values
measured at your doctors
offi ce
diff er from your
measurements.
Doctor visits can frequently
experience anxiety.
Record the daily development of the
measured values and consult your
doctor.
Display remains
blank, or is unusual, when
instrument is switched on.
Batteries are not installed
properly.
Check batteries for
correct polarity.
Device frequently fails to
measure blood pressure
values, or values measured
are too low (too high).
Cuff may not be properly
positioned.
Check the positioning of the
cuff . See Cu tting on
page 10 for proper fi tting.
Specifications
Model: BBP2000 / BBP2200
Operation principle: Oscillometric method
Display: Liquid crystal display
Measuring range: 20–280 mmHg
Pulse: 40–199 / min
Blood pressure
measurement: 20 mmHg (minimum diastolic value)
280 mmHg (maximum systolic value)
Laboratory accuracy: ± 3 mmHg (cuff pressure)
± 5 % of reading (pulse rate)
Clinical accuracy: According to AAMI-SP10 with auscultatory reference:
< 5 mmHg systematic off set
< 8 mmHg standard deviation
Infl ation: Automatic
Power supply: 2 batteries, type AAA 1.5V
Operating temperature /
atmospheric pressure: +10 °C to +40 °C (50˚F – 104˚F),860-1060 hPa (0.849 - 1.046 atm)
Storage temperature: –20 °C to +55 °C (-4˚F to +131˚F)
Humidity: 15 to 90 % relative humidity maximum
Cuff : Suitable for wrist circumference of 13.5 to 21.5 cm
(5.25 - 8.5 inches).
Clinical validation: According to AAMI-SP10 with auscultatory reference.
(Please note that a validation against intra-arterial
measurements can lead to diff erent results for devices
which are calibrated against auscultatory reference.)
Service Life: 5 years
If device is not used within specifi ed temperature and humidity ranges the technical
accuracy can not be ensured.
Type BF applied parts
See instructions for use
Subject to change without notice.
Further information
Blood pressure is subject to fl uctuations even in healthy people. Comparable
measurements always require the same conditions (quiet conditions)!
In order to receive market clearance from governmental bodies, this device was
subjected to strict clinical tests. The computer program used to measure blood
pressure values was tested by experienced cardiac specialists in Germany.
Operating temperature
55
Storage temperature
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun Vitalscan BBP2200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun Vitalscan BBP2200 in the language / languages: All languages as an attachment in your email.

The manual is 22,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info