471962
3
Zoom out
Zoom in
Previous page
1/22
Next page
3
The Braun ThermoScan thermometer has been
carefully developed for accurate, safe and fast
temperature measurements in the ear. The shape
of the thermometer probe prevents it from being
inserted too far into the ear canal and hurting the
eardrum.
However, as with any thermometer,
proper technique is very important
to obtaining accurate temperatures.
Therefore, read the use instructions
carefully and thoroughly.
Important
The operating ambient temperature range for
this thermometer is 50 104 °F (10 40 °C).
Do not expose the thermometer to temperature
extremes (below –4 °F / –20 °C or over 122 °F /
50 °C) nor excessive humidity (> 95 % RH).
This thermometer must only be used with
genuine Braun ThermoScan Lens Filters. Other
lens filters can lead to inaccuracy.
To avoid inaccurate measurements always use
this thermometer with a new, clean lens filter
attached.
If the thermometer is accidentally used without
a lens filter attached, clean the lens (see «Care
and cleaning»).
Keep lens filters out of reach of children.
This thermometer is intended for household
use only.
Use of this thermometer is not intended as a
substitute for consultation with your physician.
Body temperature
Normal body temperature is a range. The following
table shows that this normal range also varies by
site. Therefore, measurements from different sites
should not be directly compared.
A person’s normal temperature range tends to
decrease with age. The following table shows
normal ThermoScan ranges by age.
The range of normal also varies from person to
person and fluctuates throughout the day.
It is therefore important to determine normal
temperature ranges. This is easily done using
Braun ThermoScan. Practice taking temperatures
on yourself and healthy family members to
determine each person’s normal temperature
range.
Note: When consulting your physician, com-
municate that the ThermoScan temperature is a
temperature measured in the ear and if possible,
note the individual’s normal ThermoScan
temperature range as additional reference.
1. Chamberlain, J.M., Terndrup, T.E., New Light on Ear Thermometer
Readings, Contemporary Pediatrics, March 1994.
2. Chamberlain, J.M., et al., Determination of Normal Ear
Temperature with an Infrared Emission Detection Thermometer,
Annals of Emergency Medicine, January 1995.
Normal ranges by site:
Axillary
1
: 94.5 – 99.1 °F 34.7 – 37.3 °C
Oral
1
: 95.9 – 99.5 °F 35.5 – 37.5 °C
Rectal
1
: 97.9 – 100.4 °F 36.6 – 38.0 °C
ThermoScan
2
: 96.4 – 100.4 °F 35.8 – 38.0 °C
Normal ThermoScan ranges by age
2
:
0 – 2 years 97.5 – 100.4 °F 36.4 – 38.0 °C
3 – 10 years 97.0 – 100.0 °F 36.1 – 37.8 °C
11 – 65 years 96.6 – 99.7 °F 35.9 – 37.6 °C
> 65 years 96.4 – 99.5 °F 35.8 – 37.5 °C
English
6026360_KAZ_IRT3020 Seite 3 Montag, 13. August 2007 1:16 13
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun Thermoscan 6026 - IRT 3020 CO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun Thermoscan 6026 - IRT 3020 CO in the language / languages: English, French, Spanish as an attachment in your email.

The manual is 0,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Braun Thermoscan 6026 - IRT 3020 CO

Braun Thermoscan 6026 - IRT 3020 CO User Manual - German - 20 pages

Braun Thermoscan 6026 - IRT 3020 CO User Manual - German, Dutch, French, Italian - 54 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info