672109
6
Zoom out
Zoom in
Previous page
1/60
Next page
8 9
Situation Solution
Ambient
temperature is not
within the allowed
operating range
(10–40 °C or
50–104 °F).
Allow the thermometer to remain
for 30 minutes in a room where
the temperature is between
10 and 40 °C or 50 and 104 °F.
HI = too high
LO = too low
Temperature taken
is not within typical
human temperature
range (34–42.2 °C or
93.2–108 °F)
Make sure the probe tip and lens
are clean and a new, clean,
disposable lens lter is attached.
Make sure the thermometer is
properly inserted. Then, take a
new temperature.
System error Reset the thermometer
by removing the battery and then
replacing it again, wait 1 minute,
then turn on again.
Please contact your authorized
Service Center (See Guarantee
Card).
Battery is low. Insert new battery.
Battery is too low.
Device cannot be
powered on to the
ready state.
Insert new battery.
Do you have any further
questions?
Please contact your authorized
Service Center (See Guarantee
Card).
Changing the temperature scale
Make sure the thermometer is turned o. Press
and hold down the <<start>> button. Keep
holding down the <<start>> button and after
about 3 seconds the display will start to cycle
between temperature scales (°C or °F).
Release the start button when the desired scale
is shown. This will reset the thermometer to the
new temperature scale.
Replacing the battery
The thermometer is supplied with one 3V Lithium cell battery
(type 2032). Insert new battery when the low battery symbol
appears on the display.
The battery door design is
intended to prevent a small
child from easily opening the
battery door to address a
possible choke hazard. Open
the battery compartment by
inserting a narrow pointed object such as a ball point pen or
paperclip into the small hole above the battery door (8). While
pressing into the hole slowly slide back the battery door with
the other hand.
To close battery door align the tabs along the side of the
battery into the battery compartment and slowly slide back
into position until the door clicks into its locked position.
Calibration
This product has been calibrated at the time of manufacture.
If used according to the use instructions, periodic calibration is
not required. If at any time, you question the measuring accuracy,
please contact our service representative (see last page for
contact information) or visit www.hot-europe.com/support.
Manufacturing date is given by the LOT number located in the
battery compartment.
The rst three (3) digits after LOT represent the Julian date that
the product was manufactured and the next two (2) digits
represent the last two numbers of the calendar year the
product was manufactured. The last identiers are the letters
that represent the manufacturer.
An example: LOT 11614fam, this product has been
manufactured on the 116th day of the year 2014.
English
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun ThermoScan 5 - IRT3030 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun ThermoScan 5 - IRT3030 in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 19,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info