454436
4
Zoom out
Zoom in
Previous page
1/22
Next page
4
English
Our products are engineered to meet the
highest standards of quality, functionality and
design. We hope you enjoy your new Braun
EasyStyle.
Notice: Remove the sole plate label, if any,
before first use.
–––––––––––––––––––––––––––––––––––––––––
Important safeguards
Before using the iron, read the use instruc-
tions completely. Keep the use instructions
during the entire life of the iron.
Make sure your voltage corresponds to the
voltage printed on the iron. Connect the
iron to alternating current only.
Always unplug the iron before filling with
water and make sure the steam button is
in its lower position (steam off). Always pull
the plug, not the cord. The cord should
never come in contact with hot objects or
with the hot sole plate.
Never immerse the iron in water or other
liquids.
During ironing pauses, always place the
iron upright on its heel rest. Unplug it when
leaving the room, even if only for a short
time.
Never pull out the steam button (3) during
ironing.
Keep the iron away from children.
Electric irons combine high temperatures
and hot steam that could lead to burns.
Check the cord regularly for possible
damage.
If the appliance (including cord) shows any
defect, stop using it and take it to a Braun
Service Centre for repair.
Faulty or unqualified repair work may
cause accidents or injury to the user.
–––––––––––––––––––––––––––––––––––––––––
A Description
1 Spray nozzle
2 Water tank opening
3 Steam button
3a Steam regulator
4 Spray button
5 Power shot button
6 Temperature selector
7 Temperature pilot light
B Before starting off
This iron is designed for tap water. If you
have extremely hard water, we recommend
to use a mixture of 50% tap water and
50% distilled water. Fill the water tank to
«max» marking. Never use distilled water
exclusively. Do not add any additives
(e.g. starch).
Keep the iron in the upright position and
connect it to the mains. Select the tem-
perature according to the ironing guide on
the heel rest of the iron or on the label in
your garments.
The temperature pilot light (7) goes off,
when the desired temperature is reached
(after approx. 1 minute).
C Ironing
1 Steam on/off
For steam ironing, the temperature selector
(6) must be set within the red range.
Press the steam button (3) to start the
steam mode.
Steam on Steam off
With the steam button in its upper position,
turn
the steam regulator (3a) to adjust the
steam quantity.
2 Power shot
Prior to use, press the power shot button
(5) 3 to 4 times to activate it. Press the
power shot button in intervals of at least
5 seconds.
Power shot can be activated when dry
ironing. However, the temperature selector
has to be set in the range between «•••»
and «max».
3 Spray function
Press the spray button (4).
4 Dry ironing
Turn the steam mode off by pressing the
steam button (3) so that it catches in the
lower position.
D After ironing
Unplug the iron and press the steam on/off
button (3) so that it catches in its lower
position (steam off).
To prolong the life of the iron, empty the
water tank.
Store the cool iron in a dry place always
standing on its heel rest.
E Maintenance and cleaning
To clean the sole plate, use steel wool.
Then wipe the sole plate clean with a cloth.
Never use a scourin
g pad, vinegar nor
other chemicals.
F Cleaning the anticalc valve
The iron’s anticalc valve is located at the
lower end of the steam button (3). It has
to be decalcified regularly (e.g. when the
steam development is insufficient).
Proceed as follows:
1) Unplug the iron and empty the water tank.
2) Press the steam button so it is lifted.
3) Remove carefully (some water may now
leak from the sole plate).
4) Do not touch the anit-calc valve.
5) Immerse in vinegar (not vinegar essence)
or lemon juice until the lime becomes soft.
6) Use a non-metallic brush until all openings
are clean.
7) Rinse under running water.
8) Re-insert the steam button.
9) Press to check the steam on/off function.
Note: the iron must never be used without
the steam button.
G Decalcifying/ anticalc system
When scale particles come out of the
steam vents or when the steam
development is insufficient even after
cleaning the anticalc valve, you should
clean the steam chamber as follows:
1) Make sure the steam button is in its lower
position.
2)3) Fill water into the tank, connect to the
mains and select the «•••» temperature
setting.
4)5) Wait until the pilot light turns off.
Unplug the iron.
6)7) Hold the iron over a sink, then press the
steam button so it is lifted, carefully pull it
up, turn it and rest it in this position.
Caution:
When the steam button is pulled
up, hot water and steam will come out from
the sole plate.
8) Push back the steam button until it catches
in the lower position.
9)10) Fill water into the tank, connect to the
mains and select the «•••» temperature
setting.
11) 13) When the pilot light goes off, press
the power shot button 4 times to rinse the
iron. Disconnect the iron and wait for the
sole plate to cool off, then clean it as
described above in section E.
Note: the iron must never be used without
the steam button.
H Trouble-shooting guide
Problem Remedy
––––––––––––––––––––––––––––––––––––––
Drops Turn the steam regulator
coming out anti-clockwise to reduce
of the steam the steam or press the
vents steam button to turn the
steam off.
Take longer intervals
when pressing the power
shot button.
Select a higher tempera-
ture setting.
No steam Press the steam button
at all so that it is lifted.
Less steam Clean the anticalc valve
develops or no (see F).
steam at all
Calcium Decalcify the steam
particles chamber (see G).
coming through
the steam vents
––––––––––––––––––––––––––––––––––––––
Subject to change without notice.
This product conforms to the European
Directives EMC 89/336/EEC and Low
Voltage 73/23/EEC.
Please do not dispose of the product in
the household waste at the end of its
useful life. Disposal can take place at a
Braun Service Centre or at appropriate
collection points provided in your country.
press
press
4670362_SI 4000_MN Seite 4 Donnerstag, 22. Juni 2006 9:02 09
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun SI 4000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun SI 4000 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 0,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info