Type: FHT1000 Forehead thermometer
Measuring range: 93.2 °F – 108 °F (34 °C – 42.2 °C)
Resolution: 0.1 °F or °C
Accuracy (Laboratory) 0.4 °F, 96.8 ~ 102.2 °F
(Ambient Temperature: 60.8 °F to 104 °F)
Display: Liquid Crystal Display, 4 digits plus special icons
Acoustic: Audio:
Single long beep for 2 sec duration
Operating temperature: 60.8 °F – 104 °F (16 °C – 40 °C)
Automatic Switch-off: Approx. 20 seconds after last measurement has
been taken
Weight: 3.51oz. (with batteries), 2.72oz. (w/o batteries)
Long term storage ranges
Storage/transport temperature: –13 °F to 131 °F (–25 °C to 55 °C)
Humidity: 15–95% non condensing
Battery: (2) AAA Batteries - at least 1000 measurements
Pressure: 1 atm or kPa
See instruction of use Type BF Equipment
This infrared thermometer meets requirements established in ASTM Standard E 1965-98 (for the
thermometer system). Full responsibility for the conformance of the product to the standard is assumed
by Kaz USA, Inc., 250 Turnpike Rd., Southborough, MA 01772, USA.
ASTM laboratory accuracy requirements for the thermometer only in the display range of 96.8 °F to
102.2 °F (36 °C to 39 °C) for infrared thermometers is ± 0.4 °F (± 0.2 °C), whereas for mercury-in-glass
and electronic thermometers, the requirement per ASTM Standards E 667-86 and E 1112-86 is ± 0.2
°F ( ± 0.1 °C).
This device conforms to the following standards:
IEC 60601-1 3rd Edition «Medical electrical equipment» –
Part 1: General requirements for basic safety and essential performance
DIN EN 12470-5: 2003 «Clinical thermometers» –
IEC 60601-1-2: General requirements for basic safety and essential performance –
Collateral Standard: Electromagnetic compatibility –
Requirement and tests
NOTE: Do not use this device in the presence of electromagnetic or other interference outside the
normal range specified in IEC 60601-1-2.
Internally Powered Equipment
Continuous Operation
Not Protected against Ingress of Water
MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC.
For detailed description of EMC requirements please contact Consumer Relations.
Portable and mobile RF communications equipment can affect MEDICAL ELECTRICAL EQUIPMENT.
5
6
1
2
3
4
Tapa protectora del escaner
Escáner
Tapa de la batería
Pantalla LCD
Botón de temperatura
Botón de encendido
1
2
3
4
5
6
7


Need help? Post your question in this forum.

Forumrules
1

Forum

braun-fht-1000

Reset search

  • Can i convert the fahrenheit to celsius and display it ? Submitted on 16-12-2020 at 20:02

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun FHT 1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun FHT 1000 in the language / languages: English, Spanish as an attachment in your email.

The manual is 1,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info