9
Error Description Potential cause and remedy
Readings from
repeated
measurements differ
considerably.
Blood pressure is a
fluctuating value.
For healthy adults,
deviations of 10 to
20 mmHg are possible.
Reminder: always use the same arm
for measurements!
Cuff is not properly
fitted.
Ensure that the cuff is fitted
according to the Applying the arm
cuff section.
Readings were not
consistently taken at
heart level.
For each measurement, make sure
that the cuff is at heart level.
Talking, coughing,
laughing, moving etc.
when measuring will
influence the reading.
While measuring, relax, keep still,
do not move or speak.
Blood pressure values
measured at your
doctor’s office differ
from your
measurements.
Doctor visits can
frequently cause
anxiety.
Record the daily development of
the measured values and consult
your doctor.
Display remains
blank, or is unusual,
when instrument is
switched on.
Batteries are not
installed properly.
Check batteries for correct polarity.
Device frequently
fails to measure
blood pressure
values, or values
measured are too low
(or too high).
Cuff may not be
properly positioned.
Ensure that the cuff is fitted
according to the Applying the arm
cuff section.
Further information
Blood pressure is subject to fluctuations even in healthy people.
Comparable measurements always require the same conditions
(quiet conditions)!
In order to receive market clearance from governmental bodies, this
device was subjected to strict clinical tests.
Specifications
Model: BUA5000
Operation principle: Oscillometric method
Display: Liquid crystal display
Cuff pressure display
range: 0-299 mmHg
Pulse measurement: 40-199 beats per minute
Blood pressure
measurement range: 30-280 mmHg
Laboratory accuracy: ±3 mmHg (cuff pressure)
±5% of reading (pulse rate)
Clinical accuracy: According to EN 1060-1/-3 and ISO 81060-2
with auscultatory reference:
<5 mmHg systematic offset
<8 mmHg standard deviation
Inflation: Automatic
Power supply: 4 batteries, type AA 1.5V
Operating temperature/
atmospheric pressure/
humidity: 10 °C to 40 °C (50 ˚F to 104 ˚F)
860 to1060 hPa (0.849 to 1.046 atm)
15% to 90% relative humidity, non-condensing
Storage temperature/
atmospheric pressure/
humidity: -20 °C to 55 °C (-1 ˚F to 131 ˚F)
860 to1060 hPa (0.849 to 1.046 atm)
15% to 90% relative humidity, non-condensing
Cuff: Universal cuff (22-42 cm)
Clinical validation: According to international protocol 2002 (ESH)
Service life: 5 years
Warranty: 2 years
If device is not used within specified temperature and humidity ranges the
technical accuracy cannot be ensured.
Type BF applied parts Operating temperature
See instructions for use
55
Storage temperature
Keep dry
Subject to change without notice.
Internally powered equipment.
Continuous operation.
English
6


Need help? Post your question in this forum.

Forumrules
1

Forum

braun-bua5000---exactfit-1

Reset search

  • Hello! I would like to know what mean the AGG error on the ecran? Thanks Submitted on 25-1-2022 at 14:20

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun BUA5000 - ExactFit 1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun BUA5000 - ExactFit 1 in the language / languages: English, German, French, Polish, Turkish, Spanish as an attachment in your email.

The manual is 7,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Braun BUA5000 - ExactFit 1

Braun BUA5000 - ExactFit 1 User Manual - Dutch - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info