Product Description
1. LCD Display
2. Start/Stop Button
3. Memory Button
4. Set Button
5. Mode Button
6. Battery compartment cover
7. Hose Port
8. Connector
9. Hose
10. Arm Cu
11. 4x AA Alkaline Batteries (1.5V)
Inserting Batteries
Remove the battery compartment cover at the bottom of the
unit and insert 4 AA LR6 ALKALINE batteries with correct polarity
(see symbol in the battery compartment).
Note: Always re-set Date and Time after replacing
new batteries to make sure the measurement
results are stored with correct date and time.
Only discard empty batteries. They should not be disposed of in
the household waste, but at appropriate collection sites or at
your retailer.
Key Rules for Accurate Blood Pressure Measurement
Always take readings at the same time of day, ideally in the morning and evening, under
the same conditions.
• Do not measure within 30 minutes after smoking, drinking coee or eating.
Take o wrist watch and jewelry before tting the cu on the measuring arm.
While taking a measurement sit down, relax, keep still, and do not move or speak.
Wrap the cu snugly around your arm. The cu must be at heart level.
Do not vibrate the unit during measurement, or the proper measurement will not
be achieved.
• Perform measurement quietly in a relaxed position.
• Sit in a chair with your feet at on the oor.
• Do not wrap the cu over jacket or sweater sleeve or measurement cannot be done.
• Remove tight-tting clothing from your left arm.
• Do not in any way twist the arm cu.
Fig. 2
Fig. 3
• Do not inate the monitor’s cu when it is not wrapped around the arm.
• Do not attempt to disassemble or change any parts of the monitor including the cu.
• Do not drop the product or put it through strong impact.
The device is not supposed to be used if your arm has any wound or injury.
Choosing the Right Cu
For accurate measurement, it is important to choose the correct size cu which best ts your
upper arm. Choose the cu size according to your arm circumference and make sure the
bottom of the cu is 2~3 cm above your elbow.
• Small/Medium Cu = 23~33 cm arm circumference
• Large/XLarge Cu = 33~43 cm arm circumference
Applying the Arm Cu
1. Slide the end of arm cu furthest from the tube through the metal ring to a loop. The
smooth cloth should be on the inside of the cu.
2. If the cu is located correctly, the Velcro will be on the outside of the cu and the metal ring
will not touch the skin. (Fig. 4)
3. Put your left arm through the cu loop. The bottom of the cu should be approximately (2~3
cm) above elbow. The tube should lie over the brachial artery on the inside of the arm. (Fig. 5)
4. Pull the cu so that the top and bottom edges are tightened around your arm. (Fig. 6)
5. When the cu is positioned properly, press the Velcro rmly against the pile side of the cu.
6. This cu is suitable for use if the <<INDEX>> mark falls within the <<OK RANGE>> marked
by two arrows when the cu is tightened around your arm. (Fig. 7)
7. Sit on a chair and place your arm on the table so that the cu is at the same level as your
heart. (Fig. 8)
To ensure accurate measuring results, carefully read the complete use instructions.
This product is intended for household use only. Keep product and batteries away
from children.
People suering from cardiac arrhythmia, vascular constriction, arteriosclerosis in
extremities, diabetes or users of cardiac pacemakers should consult their doctor
before measuring their blood pressure themselves, since deviations in blood
pressure values may occur in such cases.
If you are under medical treatment or taking any medication, please consult your
doctor rst.
The use of this blood pressure monitor is not intended as a substitute for
consultation with your doctor.
INDEX
Fig. 5
Main
Arteries
LEFT ARM
Fig. 4
Pile Side Material
Velcro
Smooth
Cloth
Metal Ring
Fig. 6
Fig. 7
23 ~ 43 cm/ 33 ~ 43 cm
Adult Cu
INDEX
OKOK
Fig. 8
M
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun BP4600 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun BP4600 in the language / languages: English, German, French, Polish as an attachment in your email.

The manual is 17,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info