695408
14
Zoom out
Zoom in
Previous page
1/71
Next page
14
Accessories
Braun recommends changing your shaver’s
Foil & Cutter cassette every 18 months to maintain
your shaver’s maximum performance.
Available at your dealer or Braun Service Centres:
Foil & Cutter cassette: 92S/92M
Cleaning Cartridge: CCR
Braun Shaver cleaner spray
Environmental notice
Product contains batteries and / or recyclable
electric waste. For environment protection,
do not dispose of in household waste, but for
recycling take to electric waste collection
points provided in your country.
The cleaning cartridge can be disposed of with
regular household waste.
Subject to change without notice.
Trouble-Shooting
Problem: Possible reason: Remedy:
Shaver
Shaver does not start when
pressing the on / off button.
1. The shaver can only be operated
cordless.
2. Travel lock is activated.
1. Unplug the shaver.
2. Press the on / off button for 5 seconds to
unlock the shaver.
Charging does not start
when connected to power
socket or put in the Clean
& Charge Station.
1.
Sometimes charging starts
delayed (e.g. after long storage).
2. Ambient temperature is out of
valid range.
3. Power supply is not plugged into
the shaver properly.
4. Shaver is not placed properly in
the Clean & Charge Station.
1. Wait a few minutes. Charging will start
automatically.
2. Recommended ambient temperature for
charging is 5 °C to 35 °C.
3. Power supply needs to snap in.
4. Contacts of the shaver need to align with
contacts in the Clean & Charge Station.
Shaver does not charge
completely and keeps
blinking.
Ambient temperature is out of valid
range.
Recommended ambient temperature for
charging is 5 °C to 35 °C.
Unpleasant smell from the
shaver head.
1.
Shaver head is cleaned with
water.
2. Cleaning cartridge is in use for
more than 8 weeks.
1. When cleaning the shaver head with water
only use hot water and from time to time
some liquid soap (without abrasive
substances). Remove Foil & Cutter
cassette to let it dry.
2. Change cleaning cartridge at least every
8 weeks.
Battery performance
dropped significantly.
1. Foil and cutter are worn which
requires more power for each
shave.
2. Shaver head is regularly cleaned
with water but not lubricated.
1. Renew Foil & Cutter cassette.
2. If the shaver is regularly cleaned with
water, apply a drop of light machine oil on
top of the foil once a week for lubrication.
Shaving performance
dropped significantly.
1. Foil and cutter are worn.
2. Shaving system is clogged.
1. Renew Foil & Cutter cassette.
2.
Soak the Foil & Cutter cassette into hot
water with a drop of dish liquid. Afterwards
rinse it properly and tap it out. Once dry
apply a drop of light machine oil on the foil.
Shaver head is damp. 1. Drying time after automatic
cleaning was too short.
2. Drain of the Clean & Charge
station is clogged.
1. Wait until the drying process has been
completed.
2. Clean the drain with a wooden toothpick.
Clean & Charge Station
Cleaning does not start
when pressing the start
button.
1. Shaver is not placed properly in
the Clean & Charge Station.
2. Cleaning cartridge does not
contain sufficient cleaning fluid
(display blinks red).
3. Appliance is in stand-by mode.
1. Insert shaver into the Clean & Charge
Station and push it to the rear side of the
station (contacts of the shaver need to
align with contacts in the station).
2. Insert new cleaning cartridge. Press the
start button again.
3. Press the start button again.
Increased consumption of
cleaning fluid.
Drain of the Clean & Charge station
is clogged.
Clean the drain with a wooden toothpick.
– Regularly wipe the tub clean.
91611492_93XXcc_W&D_MN_Type_5793_S6-76.indd 1491611492_93XXcc_W&D_MN_Type_5793_S6-76.indd 14 20.10.17 08:1620.10.17 08:16
CSS APPROVED Effective Date 23Oct2017 GMT - Printed 22Nov2017 Page 14 of 76
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun 9355s - 5793 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun 9355s - 5793 in the language / languages: All languages as an attachment in your email.

The manual is 7,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info