Especificaciones
Modelo: BP 2510
Sistema de medición: Método oscilométrico
Pantalla: Pantalla de cristal líquido
Rango de medición: 0 – 300 mmHg (presión de muñequera)
40 – 160 / min(medida del pulso)
Medición de la presión arterial: 50 mmHg (Valor mínimo diastólico)
250 mmHg (Valor máximo sistólico)
± 3 mmHg (presión en muñequera)
± 5 % (pulso)
Precisión clínica: Deacuerdo con AAMI-SP10 referencia oscultatoria:
< 5 mmHg compensado sistemático
< 8 mmHg desviación estandar
Inflado: Automático, adaptado a la presión arterial
Desinflado: Válvula de control electrónico adaptado a la frecuencia
cardíaca.
Tipo de pilas: 2 pilas, tipo LR 03 (AAA)
(ej. Duracell Ultra)
Rango de temperatura
de funcionamiento: + 10 °C a + 40 °C
Rango de temperatura
de almacenamiento: – 20 °C a + 60 °C
Humedad: Hasta 85% humedad
Manguito: Diámetro de circunferencia: 13.5 a 20 cm
Evaluación clínica: de acuerdo con AAMI-SP10 con referencia a
auscultación
(Nota: Esta validación frente a métodos intra-arteriales puede dar lugar a resultados
diferentes a los obtenidos con dispositivos validados frente a métodos de auscultación)
Aparato del tipo BF
Sujeto a modificaciones sin previo aviso.
Este aparato cumple los siguientes estándares:
DIN EN 60601-1: 3/96 «Aparatos Eléctricos Médicos»
Parte 1: Requisitos generales de seguridad
DIN EN 1060-1: 12/95, AMD 1 09/02 «Estigmomanómetros no invasivos»
Parte 1: Requisitos generales
DIN EN 1060-3: 9/97 «Estigmomanómetros no invasivos»
Parte 3: Requisitos suplementarios de los sistemas electro- mecánicos de medición
de la presión arterial.
Este producto cumple con la directiva EC 93 /42 / EEC
(Directiva para Dispositivos Médicos).
0297
6064013_BP2510_S.5-52 Seite 42 Mittwoch, 5. Februar 2003 12:07 12
42


Need help? Post your question in this forum.

Forumrules
1

Forum

braun-6054

Reset search

  • Everything works but the cuff inflation. The noise it makes when it inflates does work. The cuff wrap around isn't blowing up. Submitted on 8-10-2021 at 20:15

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Braun 6054 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Braun 6054 in the language / languages: English, Dutch, French, Italian, Polish, Portuguese, Spanish as an attachment in your email.

The manual is 1,96 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info