32
Cable H05VVF - T105
or H05V2V2F - T90
Cross section of
conductors in mm2
Fuse
220-240 V~- 50/60 Hz
All-gas and mixed
3 conductors of
which 1 is to be
earthed
1
10 A
CROSS SECTION OF THE CABLE TO USE
Installing your hob in all simplicity
Hobs are delivered with a three-
conductor (phase + ground + neutral)
H05VVF- T105 or H05V2V2F - T90
1mm section cable, ref. SAV :
77X3767 (6470.1516) and must be
connected to a 220-240 V~ single pha-
se mains supply by the intermediary of
a two phase + earth + CEI 60083
standardised neutral plug, or a single
pole cut-off device with a contact ope-
ning by at least 3mm.
The mains plug must be accessible af-
ter installation.
Electrical connections
The protective conductor (green/yellow) is connected to the earth
connection on the hob and therefore must also be connected to an external
earth connection .
Use a 10 A fuse.
If the power supply cable is damaged, it must be replaced with a cable or a spe-
cial unit available from the manufacturer or his After Sales Service.
● Mixed and all-gas hobs