Operation
Before any work on the vacuum cleaner itself, pull the
mains plug.
Starting Operation
Observe correct mains voltage! The voltage of the pow-
er source must agree with the voltage specified on the
nameplate of the vacuum cleaner. Equipment marked
with 230 V can also be operated with 220 V.
Only use an undamaged filter (no cracks, small holes,
etc.). Replace a damaged filter immediately.
Products sold in AUS and NZ only: Use a residual current de-
vice (RCD) with a rated residual current of 30 mA or less.
The vacuum cleaner may generally not be used in rooms
where the danger of an explosion exists.
To save energy, only switch the vacuum cleaner on when us-
ing it.
To ensure optimal vacuuming performance, always complete-
ly unwind the vacuum hose 16 from the vacuum cleaner lid 7.
Dry Vacuuming
Vacuuming of deposited dust
UniversalVac 15:
AdvancedVac 20:
Extraction of dust resulting from running power tools
(see figure E)
Fit the extraction adapter 17 (see “Fitting the extraction
adapter or curved nozzle”, page 16).
Insert the extraction adapter 17 into the dust extraction
outlet for the power tool.
Note: When working with power tools that have a low air feed
into the vacuum hose (e.g. jigsaws, sanders, etc.), the air dif-
fuser 31 of the vacuum hose 16 must be opened. This will im-
prove the total output of the vacuum cleaner and the power
tool.
To do so, turn the ring above the air diffuser 31 until the max-
imum opening is produced.
AdvancedVac 20:
A socket outlet with earthing contact 4 is integrated in the
vacuum cleaner. An external power tool can be connected
there. Observe the maximal allowable load of the connected
power tool.
–To start the operation of the vac, switch on the power tool
connected to the socket 4. The vacuum cleaner starts au-
tomatically.
Switch the power tool off to end the vacuuming.
The delayed action shutdown of the Automatic Start/Stop
continues to run for up to 6 seconds in order to extract re-
sidual dust from the vacuum hose.
Wet Vacuuming
CAUTION! This appliance is not suitable for picking up
hazardous dust. Do not vacuum inflammable or explo-
sive fluids; for example, benzene, oil, alcohol, solvents.
Do not vacuum hot or burning dust. Do not operate the
machine in rooms where the danger of an explosion ex-
ists. The dusts, vapours or fluids can ignite or explode.
The vacuum cleaner may not be used as a water pump.
The vacuum cleaner is intended for vacuuming air and wa-
ter mixtures.
Before any work on the vacuum cleaner itself, pull the
mains plug.
Unlock the latches 8 and remove the vacuum lid 7.
Before wet vacuuming, remove the dust bag 29, the fabric
filter 32 and empty the container 1.
Clean the filter 33 (see “Cleaning/replacing filters”,
page 18).
Reattach the vacuum lid 7 again and lock the latches 8.
AdvancedVac 20:
Insert the rubber lip 23 into the floor nozzle 21 (see
“Changing inserts for the floor nozzle”, page 16).
The vacuum cleaner is equipped with a float. The suction pow-
er decreases when the maximum filling level is reached.
Switch the vacuum cleaner off immediately (on/off switch
5/mode selector switch 5 to the “Vacuuming” symbol).
–Empty the container 1.
AdvancedVac 20: Empty the container using the drain hole
for liquids 2.
To prevent the formation of mould after wet vacuuming:
Remove the vacuum lid 7 and leave it to dry thoroughly.
Remove the filter 33 and leave this to dry thoroughly as
well (see “Cleaning/replacing filters”, page 18).
Maintenance and Service
Maintenance and Cleaning
Before any work on the vacuum cleaner itself, pull the
mains plug.
For safe and proper working, always keep the vacuum
cleaner and ventilation slots clean.
If the replacement of the supply cord is necessary, this has to
be done by Bosch or an authorized Bosch service agent in or-
der to avoid a safety hazard.
–To switch on the vacuum cleaner, set the
on/off switch 5 to the “Vacuuming” symbol.
–To switch off the vacuum cleaner, set the
On/Off switch 5 to the “Switching Off” sym-
bol.
–To switch on the vacuum cleaner, set the
mode selector switch 5 to the “Vacuuming”
symbol.
–To switch off the vacuum cleaner, set the
mode selector switch 5 to the “Off” symbol.
–To activate the automatic
start/stop of the vacuum cleaner, set
the mode selector switch 5 to the
“Automatic Start/Stop” symbol.
–To switch off the vacuum cleaner, set the
mode selector switch 5 to the “Off” symbol.
OBJ_BUCH-3012-003.book Page 17 Wednesday, September 6, 2017 3:04 PM
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch UniversalVac 15 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch UniversalVac 15 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 19,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info