F 016 L81 568 | (26.4.17) Bosch Power Tools
Connecting to the mains
The voltage indicated on the rating
plate must correspond to the voltage
of the power source.
We recommend that this equipment
is only connected into a socket which
is protected by a circuit-breaker that
would be actuated by a 30 mA residu-
al current.
Remove the plug from socket when-
ever the machine is left unattended
for any period.
The electric supply installation
should comply with IEC 60364-1.
If the supply cord is damaged, it must
be replaced by the manufacturer, its
service agent or similarly qualified
persons in order to avoid a hazard.
If the plug is damaged, pay attention
to the following:
Plugs and sockets situated near the
work site or outdoors should be to
class IP 55 of BS 5490 to provide ad-
equate protection against ingress of
water, etc. and cable entries require
effective sealing. Rubber shrouds
should be provided over cable
glands. Drip-proof (class IP X2 of
BS 5490) plugs and sockets to
BS 4343 are suitable for use indoors
where the plug is away from the water
spray area where the appliance is in
use.
Never touch the mains plug with wet
hands.
Do not pull plug while operating the
device.
Do not run over, crush or pull the
power supply cord or extension cord,
otherwise it may be damaged. Pro-
tect the cable from heat, oil and sharp
edges.
Do not use the unit, if the power sup-
ply cord or important parts, e. g.
high-pressure hose, power gun or
safety devices are damaged.
Warning: Inadequate extension cords
can be dangerous.
If an extension cord is used, the plug
and socket must be of watertight con-
struction. The extension cord must
have a cross section in accordance
with the operating instructions and
be protected against splashed water.
The connection must not be in water.
When replacing plugs on the power
supply cable or extension lead the
spray water guard and mechanical
stability must remain intact.
Water connection
Comply with the regulations of your
water supply company.
All connecting hoses must have prop-
erly sealed joints.
Make sure that the supply hose is at
least 12.7 mm (1/2") in diameter and
is reinforced.
The appliance should never be used
on the drinking water supply without
a back flow valve. Water which has
passed the back flow valve is regard-
ed as undrinkable.
The high-pressure hose must not be
damaged (danger of bursting). A
damaged high-pressure hose must be
replaced immediately. Only use hos-
es and connections recommended by
the manufacturer.
OBJ_BUCH-2981-002.book Page 12 Wednesday, April 26, 2017 3:49 PM
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch UniversalAquatak 130 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch UniversalAquatak 130 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 12,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info