6 720 812 900 (2014/10)Uni 3000 F
4.6 Fitting the burner (accessory)
4.6.1 Fitting the burner plate (accessory)
Secure burner plate [2] with gasket [1] to burner door [3] using
hexagon bolts and washers [4].
Fig. 18 Fitting the burner plate
[1] Sealing ring
[2] Burner plate
[3] Burner door
[4] Hexagon bolt and washer
4.6.2 Fitting the burner to the burner plate
The thermal insulation in the burner door comes standard with a
200 mm hole for the blast tube. If the blast tube is larger than this, the
diameter of the aperture can be increased to a maximum of 275 mm.
The burner door must be opened to allow the burner to be fitted.
Open the burner door ( Chapter 4.5.1).
▶Push a gasket ( Fig. 18, [1]) onto the burner connector.
Screw burner ( Fig. 19, [1]) to the burner plate [2].
Cut out insulating rings [4] in accordance with the diameter of blast
tube [5].
Fill remaining gap between burner door insulation [3] and blast tube
[5] with adapted insulating rings [4].
Connect the blower connection for the sight glass with burner [1] to
ensure the sight glass remains free from deposits.
Close burner door and tighten nuts ( Chapter 4.5, page 18).
Connect burner cable to burner [1].
Fig. 19 Fitting the burner
[1] Burner
[2] Burner plate
[3] Burner door insulation
[4] Insulating rings
[5] Blast tube
4.7 Fitting the control unit (accessory)
This chapter explains how to fit the control units of the CFB controller
series and a temperature sensor set for the boiler.
Depending on the boiler size, the control unit can be mounted either on
top of the boiler or on the side.
4.7.1 For boiler sizes 420 kW to 820 kW
In Fig. 20, (overleaf), the control unit (without rear panel) and the
control unit holder [1] are shown from the rear.
Undo both screws from cover [1]. Lift off the cover.
Place the control unit with the locking tabs [4] into the holes in the
front of the control unit holder (mounted on the front of the boiler)
[5].
Pull the control unit forwards and then tip backwards. The flexible
hooks [2] must latch Into the openings [3].
NOTICE: Risk of system damage from incorrect burner.
Only use burners that meet the technical requirements
of the boiler ( Chapter 2.16, page 8).
Pre-drilled burner plates are available from the boiler
manufacturer (accessory).
The burner plate depends on the burner used.
Refer to the installation instructions of the particular
burner for how to mount and connect it.
NOTICE: Risk of system damage from incorrect or
missing insulating rings.
Only use the insulating rings supplied.
6 720 806 032-27.1ITL
3
1
2
4
6 720 806 032-29.1ITL
4
1
2
3
5
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Uni 3000 F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Uni 3000 F in the language / languages: English as an attachment in your email.

The manual is 4,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch Uni 3000 F

Bosch Uni 3000 F User Manual - English - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info