743499
6
Zoom out
Zoom in
Previous page
1/84
Next page
6
TRZ 12 T/W
English
Contents
1 Safety Notes 6
2 Details of Unit 6
3 Mounting 7
4 Electrical Connection 7
5 Operation 8
6 Important Notes 9
7 Error Localisation 9
1 Safety Notes
Correct functioning is ensured only when these
instructions are observed. We request that this
booklet be given to the customer.
Before connecting the regulator, the volt-
age supply (230 V, 50 Hz) to the heating
unit or the regulator must be interrupted.
The regulator is to be connected only in ac-
cordance with the circuit diagram with the
respective heating units.
The connection must be to the heating unit
and under no circumstances to an
exter-
nal voltage source
.
Protection against contact:
After the
electrical connection, the protective cover
must be mounted again with screws in all
cases.
2 Details of Unit
2.1 Application
Room thermostat with daily timer (TRZ 12 T)
or weekly timer (TRZ 12 W)
2-point burner control of the one-stage heat-
ing units listed below:
Controls heating circulation pumps, etc.
Intermittent pump mode with MB 40
2.2 Technical Data
Heating Unit
Elec. connec-
tion diagram
KN/K..-8 E/EC
Fig.
KN..-8 P/KP
Fig.
Heating equipment
with Bosch Eurotronic
Fig.
Other manufacturers
Fig.
Height 82 mm
Width 165 mm
Depth 42 mm
Rated voltage, regulator 230 V AC
Switching timer 24 V DC
Rated current,
switch contacts
3 (1.5) A
Regulating range 6...30 °C
Regulator output
2-Point,
potential-free
Permissible environmental
temperature
0...35 °C
Operating reserve 50 h
Protection class/Test class
II/II
Minimum switch-on time 1.5 min.
5
6
7
8
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch TRZ 12 T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch TRZ 12 T in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Spanish as an attachment in your email.

The manual is 1,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info