Installation instructions
TR2000TF – 6 720 875 992 (2021/08)
10
The installation instructions of the safety group must be followed.
Only a prototype-tested diaphragm safety valve may be installed.
A shutoff valve must not be installed between the safety valve and
floor-standing water heater.
The safety valve must be operated regularly to verify its function and
prevent it from becoming blocked, e.g. by limescale deposits.
This appliance can be used by children aged 8 years and older as well
as by persons with diminished bodily, sensory or mental perception,
or those who lack knowledge or experience, if they are monitored
or have received instruction concerning use and comprehend the
possible dangers that can result. Children may not play with the
appliance. Cleaning and maintenance by the user may not be
performed by unsupervised children.
Keep children away from the appliance.
Please monitor children to ensure that they do not play with the
appliance.
The mixer and the warm water pipe may be hot. Please inform and in-
struct children appropriately.
Do not use aggressive or abrasive cleaning detergents!
Do not use a steam cleaner.
CAUTION:
DANGER Scalding!
Hot water may escape during draining.
If the appliance needs to be drained for maintenance or to protect the
whole installation when there is a risk of frost, proceed as follows:
Close the shut-off valve in the cold water line.
Open the hot water taps on all draw-off points.
Drain the appliance using the drain valve.
Congratulations on purchasing this appliance. You have acquired a top-
quality product, which will give you a lot of enjoyment.
Please read this installation and operating instruction manual
carefully, then act accordingly! Store for future reference.
2 Installation instructions
Install the floor-standing water heater as described in the illustrated
section. Observe the instructions in the text.
The illustrations can be found at the end of the instruction manual.
2.1 Installation
For economic reasons the installation location should be near the most
frequently used tap connection.
2.1.1 Description of the appliance
The interior of the steel tank has been specially enamelled to prevent
corrosion and has been fitted with a protective anode. This anode
protects the inside of the cylinder from corrosion. The exterior has been
directly insulated with foam which cannot be removed. Cover the
appliance with the supplied protective jacket only when the installation
work is complete.
The universal flange enables electrical connections for single or double
circuit operation.
Single circuit operation
The appliance automatically heats up at any temperature setting subject
to the availability of power.
Dual circuit operation
During off-peak tariff periods (cheap rate periods of power supply
utilities), the appliance automatically heats up the water content with
standard heating output at any temperature settings. In addition, you
can start the booster heater during peak tariff periods.
Circulation pipes should be avoided on account of the high heat losses.
The circulation connection is located where the thermal insulation is
noticeably indented.
Parts supplied (Fig. 1 )
1 Floor-standing water heater
2 Protective jacket
Appliance design (Fig. 2 )
3 Hot-water outlet
4 Protective anode
5 Circulation connection piece
6 Mark for circulation connection piece
7 Steel tank, enamelled interior
8 Thermal insulation
9 Temperature selector switch
10 Push-button
11 Heating flange
12 Cold-water inlet
Dimensions (Fig. 3 )
Water connection (Fig. 4 )
Comply with DIN 1988 and the regulations issued by the water
company.
Materials for cold-water and hot-water pipes
Water pipe made of steel, copper or plastic.
If plastic pipes are used, only install pipe systems made of crosslinked
polyethylene (high-density polyethylene) according to DIN 16893 series
2 (20 bar), checked in accordance with DVGW work sheets W 531 and
W 532 with the corresponding DVGW mark of conformity.
Information regarding the suitability and quality of other plastic pipes
without the above-mentioned design approval information can only be
provided by the pipe manufacturer.
Copper pipes are recommended if there is a risk of corrosion.
If using copper and steel materials, they must be joined in the following
sequence, as seen from the flow of direction: Copper comes after steel.
This will avoid corrosion by local cell formation.
Stipulated combinations:
Cold-water pipe made of copper: hot-water pipe made of copper or
plastic
Cold-water pipe made of steel: hot-water pipe made of steel, copper
or plastic
Cold-water pipe made of plastic: hot-water pipe made of steel,
copper or plastic
Pressure reducing valve
The floor-standing water heater is designed to operate at pressures not
exceeding 0,6 MPa (6 bar). A pressure reducing valve must be situated
in the cold-water pipe if the water mains pressure exceeds 0,5 MPa (5
bar). If the water mains pressure exceeds 1,0 MPa (10 bar), a second
pressure reducing valve must be connected in series.
Installation example (Fig. 4 )
1 Thermostat
2 Time switch
3 Circulation pump
4 Non-return valve
5 Outlet valve
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Tronic TR2000TF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Tronic TR2000TF in the language / languages: English, German as an attachment in your email.

The manual is 1.92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info