TR 200
English
When the lid is closed the time is shown and
the measured room temperature is indicated
(in 0.5 °C steps).
6.1 The “1
st
operating level”
6.1.1 Control knob (k)
The room temperature to which the regulator
will keep in standard heating mode is set with
the control knob (k) .
The regulator will always regulate the temper-
ature to this value when the respective red
control light (l) is on.
If the control knob (k) is set to “5”, the re-
spective red control light (l) is off. The regula-
tor will then set the temperature to approx.
5°C so that frost protection in this room is
guaranteed. This means that the heating sys-
tem is switched off when the temperature ex-
ceeds 6°C.
6.1.2 The operating conditions
Automatic operating mode
The basic setting of the regulator is automatic op-
erating mode.
Automatic operating mode means automatic
changeover between standard heating opera-
tion and economical operation at the times
pre-set with the time switch (e).
During standard heating operation (=“day”),
the regulator regulates the room temperature
to the value set with the control knob (k), the
respective red control light (l) is on.
During economical heating operation
(=“night”), the regulator regulates the room
temperature to the set economic temperature,
the respective red control light (l) is off. (Pre-
setting of economic temperature see
chapter 6.2.1)
Note: Each time the automatic operating
mode is switched off a control light
comes on or a text is displayed.
The operating mode can be
switched back to automatic opera-
tion at any time.
Button
“Continuous heating mode” (g)
When this button is depressed (g) continu-
ous heating operation is activated.
The regulator continuously regulates the room
temperature to the value set with the control
knob (k) .
The respective red control light (f) is on.
The respective red control light (l) is also on
(unless the control knob (k) is set to “5”).
The economical operating mode set at the
time switch is ignored.
The operating mode “continuous heating” will
be activated until:
the button (g) is depressed again; the
regulator will switch back to the automatic
operating mode
or
the button (h) is depressed again; the reg-
ulator will switch back to economical operat-
ing mode.
In both cases the respective red control
light (f) turns off and the regulator will regulate
the room temperature to the set value.
Depress this button if you exceptionally
go to bed late (e.g. because of a party). Switch
back to automatic operating mode later.
In case of an illness it might be more comfort-
able to have a higher room temperature (con-
tinuous heating operation). In this case, do not
forget to switch the regulator back to the auto-
matic operating mode.
During a winter holiday or during the summer,
a low room temperature for a longer period
can be selected by depressing the button
“continuous heating” and additionally reduc-
ing the temperature with the control knob
(k).
Button
“Economical operating mode” (h)
When the button (h) is depressed the eco-
nomical operating mode is switched on.
The regulator continuously regulates the room
temperature to the value set with the control
knob “economic temperature” (setting the
economic temperature see chapter 6.2.1).
25
15
5
3010
20°C
Tip
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch TR 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch TR 200 in the language / languages: Dutch as an attachment in your email.

The manual is 1,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch TR 200

Bosch TR 200 Quick start guide - German - 1 pages

Bosch TR 200 Usermanual and installation guide - German - 46 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info