TR 100
English
1 Safety Instructions
The regulator is to be used only in con-
nection with the listed gas heating units.
The respective circuit diagram must be
observed.
The regulator must under no circum-
stances be connected to the 230 V
mains.
Before installing the regulator, the volt-
age supply (230 V, 50 Hz) to the heating
unit must be interrupted.
The regulator is not suited for installa-
tion in damp rooms.
2 Application
TR 100 is a room temperature regulator with a
digital time switch (daily programme for one
heating and one reduction starting time; equal
for all days of the week) for controlling the gas
heating units with continuous control listed be-
low.
TR 100 is in accordance with the regulations
and is recommended for floor-areas up to ap-
prox. 80 m
2
.
The room temperature regulator TR 100 is not
suited for buildings with underfloor heating
systems. In those buildings we recommend
the use of a regulator controlled by atmos-
pheric conditions.
2.1 Scope of delivery
TR 100 includes the room temperature regu-
lator with inserted brief operating instructions
(illustration ).
2.2 Accessory
An external room temperature sensor RF 1 in
addition to TR 100 is available as accessory.
For example, the use of this temperature sen-
sor is of advantage when the mounting loca-
tion of the regulator is not suited for measure-
ment of temperature (see chapter 4).
Furthermore, a remote control switch (e.g. a
telephone commander) can be connected by
customers (see chapter 6.7).
The remote control switch must be equipped
with a potential-free contact which is suited for
5 V DC.
3 Technical Data
4 Mounting
Before mounting the regulator, the volt-
age supply (230 V, 50 Hz) to the heating
unit must be interrupted.
4.1 Selecting the mounting location
It is important for the regulation quality of
TR 100 to select a suitable mounting location.
The installation room must be suitable for the
temperature regulation of the complete heating
system. The radiators installed in those rooms
must not be equipped with thermostatic valves.
Instead, hand valves with pre-adjustment
should be installed so that the heating output of
the radiators in the installation room of TR 100
can be set to the lowest possible value.
For the mounting location, select an interior
wall if possible and take care that neither
draughts nor heat radiation (not from behind
the wall, either, e.g. through ducts or hollow
walls, etc.) can have effects on the regulator.
Heating unit Mains
connection
Malfunction
remote indi-
cator active
ZE/ZWE .. - 2 K... Illustr. no
ZE/ZWE .. - 2 A... Illustr. no
ZR/ZWR/ZSR...-3 Illustr. no
ZR/ZWR/ZSR...-4 Illustr. no
Heating equipment
with
Bosch Heatronic Illustr. yes
9
10
10
10
11
2
Dimensions
see illustration
Rated voltage 24 V DC
Rated current 0.02 A
Regulating range 5 to 30 °C
Regulator output constant,
2.5 to 21 V DC
Permissible ambient
temperature 0 to +40 °C
Operating reserve approx. 2 hrs.
Protection class IP 20
3
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch TR 100 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch TR 100 in the language / languages: Dutch as an attachment in your email.

The manual is 0,74 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch TR 100

Bosch TR 100 User Manual - English - 68 pages

Bosch TR 100 Quick start guide - German - 1 pages

Bosch TR 100 Usermanual and installation guide - German - 30 pages

Bosch TR 100 User Manual - Polish - 68 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info