2 Product information
2.1 Determined use
Enamelled DHW cylinders are designed for heating and storing potable
water. Country-specific regulations, guidelines and standards for
potable water must be observed.
Enamelled DHW cylinders may only be used in sealed unvented systems.
Any other use is considered incorrect. Any damage resulting from non-
intended use is excluded from liability.
2.2 Scope of delivery
500 litre cylinder
Storage cylinder made of PU rigid foam
Thermal insulation:
ErP “B”: additional thermal insulation 40 mm
ErP “C”: foil jacket on flexible foam underlayer
Casing lid
Upper insulation
Hand-hole cover
Technical documents
750/1000 litre cylinder
Storage tank
PU rigid foam halves
Thermal insulation:
ErP “B”: polystyrene jacket, packaged separately
ErP “C”: foil jacket on flexible foam underlayer
Casing lid
Upper insulation
Floor insulation
Round hand-hole cover with insulation
Bag with accessories:
Rectangular hand-hole cover
Fleece strip
Fleece circular blank
Compass and plug
Technical documents
2.3 Specification
Requirements
for potable water
Unit Value
Water hardness ppm CaCO
3
grain/US gallon
°dH
°fH
> 36
> 2.1
> 2
> 3.6
pH value 6.5...9.5
Conductivity μS/cm 130...1500
Table 2 Requirements for potable water
Unit W 500-5X B W 500-5X C W 750-5X B W 750-5X C W 1000-5X B W 1000-5X C
Dimension Fig. 1, page 66
Memory
Available capacity (total) Itr 500 500 768 768 991 991
Usable DHW volume
1)
at
DHW outlet temperature
2)
:
1) Without recharging; set cylinder temperature 60 °C
2) Mixed water at draw-off point (at 10 °C cold water temperature)
45 °C Itr 714 714 1104 1104 1449 1449
40 °C Itr 833 833 1288 1288 1690 1690
Maximum cold water flow rate l/min 50 50 77 77 101 101
Maximum DHW temperature °C 95 95 95 95 95 95
Maximum operating pressure, potable
water
bar 10 10 10 10 10 10
Highest design pressure
(cold water)
bar 7.8 7.8 7.8 7.8 7.8 7.8
Maximum DHW test pressure bar 10 10 10 10 10 10
Outputs in conjunction with an external SLP3 (500 litres) or SLP5 (750/1000 litres) heat exchanger
Continuous output
(at 70 °C flow temperature, 45 °C DHW
outlet temperature and 10 °C cold
water temperature)
kW
l/min
160
66
160
66
310
127
310
127
310
127
310
127
Performance factor N
L
3)4)
3) Performance factor NL=1 in accordance with DIN 4708 for 3.5 occupants, standard bath tub and kitchen sink. Temperatures: cylinder 60 °C, DHW outlet temperature 45 °C
and cold water 10 °C. Measured at max. heat output. If the output is reduced, NL becomes smaller.
4) Performance factor NL and continuous output in conjunction with SLP5 primary store system.
kW 55 55 126 126 140 140
Heat-up time at rated output min 11 11 9 9 11 11
Table 3 W specifications
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch Stora W 500 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch Stora W 500 in the language / languages: English, German, Dutch, French, Spanish as an attachment in your email.

The manual is 2,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info