Installation and connection en
39
Waste-water connection
1. The required work sequence can be
found in the installation instructions.
If required, fit a siphon with an
drainage connection.
2. Connect the waste-water hose to the
drainage connection of the siphon
with the enclosed parts.
Ensure that the drainage hose is not
kinked, crushed or twisted and that
there is no cover plate in the
drainage to prevent the waste water
from flowing out!
Drinking water connection
1. Fasten the drinking water connection
to the tap according
to the installation instructions using
the enclosed parts.
Ensure that the drinking water
connection is not kinked, crushed
or twisted.
2. When replacing the appliance,
always use a new water supply hose.
Water pressure:
At least 0.05 MPa (0.5 bar), maximum
1 MPa (10 bar). At a higher water
pressure: connect pressure-reducing
valve ahead.
Inlet rate:
Minimum 10 litres/minute
Water temperature:
Cold water; hot water max. temperature
60 °C.