IP Camera 200 Series Advanced Mode | en 49
Bosch Security Systems Installation and Operation Manual AR18-09-B003 | v1.1 | 2010.05
It is only necessary to change the white point offset for special
scene conditions.
Main frequency and Operation environment
Select 50 Hz or 60 Hz as the main frequency, and Indoor or
Outdoor for the operation environment.
Exposure/frame rate
Auto exposure/frame rate: the camera automatically sets
the framerate. The camera tries to maintain the selected
default shutter speed as long as the light level of the scene
permits.
Select a minimum frame rate from 4 to 30 fps.
Fixed exposure: allows a user-defined shutter time.
Select the shutter speed when exposure control is set to
fixed (1/30, 1/50, 1/60, 1/100, 1/120, 1/250, 1/500, 1/
1000, 1/2500, 1/5000, 1/7500, or 1/15000).
Note:
Shutter time is affected by frame rate in auto framerate mode.
For example, if the frame rate is 30 IPS, the longest shutter
time available is 1/30s.
Default
Click Default to set all video values to their factory setting.
6.4.4 Audio
Select the microphone or line-in connector as the Audio input
or switch it off. Adust the Input volume with the slider.
Switch the Audio output On or Off.
6.4.5 Installer Options
Disable the Camera LED on the camera to switch it off.
Enable Mirror image to obtain a mirror image display of the
camera picture.
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch NDC-225-P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch NDC-225-P in the language / languages: English as an attachment in your email.

The manual is 2,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch NDC-225-P

Bosch NDC-225-P Installation Guide - German - 115 pages

Bosch NDC-225-P Installation Guide - Dutch - 110 pages

Bosch NDC-225-P Installation Guide - French - 112 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info