697306
29
Zoom out
Zoom in
Previous page
1/192
Next page
Commissioning | 29
6 720 815 257 (2014/10)MS 200
TS19 Temperature sensor at middle of cylinder 1 (transfer /
primary store system)
TS20 Temperature sensor at top of cylinder 2 (transfer system)
VS1 3-way valve for central heating backup ( )
VS2 3-way valve for cylinder 2 (solar thermal system) with valve
VS3 3-way mixer for return temperature control ( )
VS4 3-way valve for cylinder 3 (solar thermal system) with valve
WM1 Water meter
4 Commissioning
4.1 Setting the coding card
When the coding switch is in a valid position, the indicator lights up
green continuously. When the coding switch is in an invalid position or an
intermediate position, the indicator does not light up initially. It then
starts to flash red.
Heat pump
Other heat sources
1... Solar thermal system 1
3... Transfer system 3
4 ... Primary store system 4
II Sense II
III CS 200
IV HPC 400/HMC300
4.2 System and module commissioning
4.2.1 Solar system settings
1. Set the coding card.
2. Set the coding card on other modules as applicable.
3. Switch on the power supply (mains voltage) to the entire system.
When the module indicator lights up green continuously:
4. Commission and set up the user interface as described in the
accompanying installation instructions.
5. Select the installed functions in the Solar settings > Change solar
configuration menu and add them to the solar thermal system.
6. Check the settings for the solar system at the user interface and
adjust the solar parameters if required.
7. Start the solar system.
4.2.2 Settings for transfer and primary store systems
1. Set coding switch at MS 200 for the primary store system to 7, or 8
for the transfer system.
2. Set the coding card on other modules as applicable.
3. Switch on the power supply (mains voltage) to the entire system.
If the status indicators on the modules light up green continuously:
4. Commission and set up the user interface as described in the
accompanying installation instructions.
5. Select the functions installed in the Transfer settings > Change
transfer configuration menu and add to the transfer system or
adjust the primary store system in the DHW settings menu.
6. Check the system settings at the user interface and, if required,
adjust the transfer parameters or DHW system I settings.
First make all electrical connections correctly and only
then carry out the commissioning!
Follow all installation instructions for all components
and assemblies in the system.
Only switch on the power supply when all modules
are set up.
NOTICE: Risk of damage to system through pump failure!
Fill and vent the system before switching it on so that
the pumps do not run dry.
System
Heat
appliance
Programming
unit
Coding,
module 1
Coding,
module 2
II III IV
MS 200
MS 100
MS 200
MS 100
1 A ... 1– – –
1 A ... 1– – 2
1 B ... 1– – –
1 B ... 1– – 2
1 A ... – – 10 – –
1 A ... – – 10 – 2
3... – – 8– – –
4 ... – – 7– – –
Table 14 Assigning the module function via coding switch
If the coding switch at the module is set to 8 or 10, do not
establish the bus connection with a heat source.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch MS 200 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch MS 200 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 18,85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info