9
Bosch Security Systems | 18 August 2005
LTC 8016/90 | Instruction Manual | Installation
NOTE: The video signal and Bilinx control
data require unobstructed two-way
communication. Do not place active video
devices in the coax line, because it will block
the control data signals.
Passive devices, such as ground loop isolation
transformers or other devices specifically designed to
support Bilinx communication, can be placed in the
coax line. In some configurations, it may be possible
to connect an active device after the video passes
through the head-end control unit. For sample
applications, refer to the Typical Configuration Diagrams
Section found later in this manual.
When an operating camera is connected to the
Interface Unit, the video channel LED illuminates
GREEN to indicate the presence of an acceptable
video signal. As Bilinx control data is sent to or
received from Bilinx-enabled cameras, the respective
channel LED flashes accordingly.
4.4 Group ID Number
The rear panel of the Interface Unit contains a set of
3 rotary switches, as shown below. Use the straight
slot side of the supplied offset screwdriver to set the
switches to the necessary value.
These switches are used to identify the group of
cameras to be connected to the Interface Unit. Each
group consists of 16 cameras in consecutive order,
and the group must always end at an exact multiple
of 16. For example, the lowest camera group range
is from 1 to 16. The next group range is from
17 to 32, etc., up to the last group (camera range of
9985 to 9999). If multiple Interface Units are used in
the same system, each Group ID number must be
unique.
The following chart summarizes the supported switch
settings:
When the Interface Unit is connected to an Allegiant
system using the Allegiant data interface protocol,
the Group ID switches should always be set to
correspond to the physical camera numbers used in
the system. For control systems that use the biphase
data interface, the switches should be set to
correspond to the controller’s logical camera
configuration.
After a change is made in a large Allegiant system
with multiple Interface Units, 30 seconds may be
required before the new settings take effect in all
Interface Units.
Setting 900 is reserved for factory use. If the Interface
Unit is inadvertently set to this value for more than
5 seconds before being set to its correct value, a
power off/on may be required for the unit to return
to its normal operating mode.
Select the step below that applies to your specific
system configuration.
BOSCH
POWER / DATA
Allegiant Bilinx Data Interface
Interface
Data
LTC 8016/90
Video + Data
NVT-211 or
NVT-213A Baluns
(Sold separately)
LTC 4631
F/O Module
Fiber Cable Length
600 m ( 2000 ft) max
Typical CAT-5
UTP Cable
225 m (750 ft)
max
LTC 4630
F/O Module
Coax
Coax
Bilinx-enabled
AutoDomes
Allegiant or Biphase
Control System
Switch Setting Use
001 to 625 Valid switch settings used for Allegiant and biphase
controller interfaces
901 to 931 Settings used in Allegiant interface mode to
terminate RS-485 data line
000 Reserved; setting is used during firmware upgrades
900 Reserved; setting is used by the factory
GROUP ID
0
2
6
4
8
0
2
6
4
8
0
2
6
4
8
Figure 2 Interface Unit Used with Other Video
Transmission Technologies
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch LTC8016 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch LTC8016 in the language / languages: English as an attachment in your email.

The manual is 0,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info