5
Wall clearance
If the appliance is positioned in the corner of a room or
a recess, minimum clearances at the sides must be
maintained so that the heated air is able to escape
unimpeded and the appliance door can be fully
opened.
Observe the room temperature and
ventilation requirements
Room temperature
The appliance is designed for a certain climate class.
Depending on the climate class, the appliance can be
operated at the following ambient temperatures.
The climate class is specified on the rating plate.
Note
The appliance is fully functional within the room
temperature limits of the specified climate class. If an
appliance in the SN climate class is operated at lower
ambient temperatures, damage to the appliance can be
excluded up to a temperature of +5 °C.
Ventilation
The heated air must be able to escape unimpeded.
Otherwise, the refrigerating unit has to work harder,
which increases the appliance's power consumption.
Therefore:
Never cover over or block the air vent.
Keep minimum distances to walls and furniture.
Connecting the appliance
After setting up the appliance, wait for at least 4 hours
before starting the appliance up. The oil contained in
the compressor may have been displaced into the
refrigeration system during transport.
Before starting the appliance up for the first time, clean
its interior (see section headed Cleaning the
appliance).
Do not remove the transit locks from the shelves and
trays until the appliance has been installed.
Electrical connection
The socket must be near to the appliance and easily
accessible after the appliance has been installed.
The appliance conforms to protection class I. Connect
the appliance to a 220-240 V/50 Hz alternating current
supply using a socket with protective earthing
conductor which has been correctly installed. The
socket must be protected by a fuse with a rating of
10 A to 16 A.
In the case of appliances operated outside of Europe,
check whether the voltage and type of current specified
conform to the values of your electricity grid. You will
find this information on the rating plate.
m Warning
The appliance must never be connected up to an
electronic energy-saving socket.
Sinusoidal-commutated and line-commutated inverters
can be used with our appliances. Line-commutated
inverters are used with photovoltaic systems that are
connected directly to the national grid. Sinusoidal-
communicated inverters must be used with standalone
applications (e.g. on ships or mountain huts) that do
not have a direct connection to the national grid.
Climate class Permissible room temperature
SN +10 °C to 32 °C
N+16 °C to 32 °C
ST +16 °C to 38 °C
T+16 °C to 43 °C
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch KTL15NWFAG at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch KTL15NWFAG in the language / languages: English as an attachment in your email.

The manual is 1.16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Bosch KTL15NWFAG

Bosch KTL15NWFAG User Manual - German, Dutch, French, Italian - 78 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info