665310
52
Zoom out
Zoom in
Previous page
1/118
Next page
en
52
Specification and performance
data sheet
For filter model: 9000 225 170
Using replacement cartridge: 9000 077 104
The model was tested by NSF International with
reference to ANSI/NSF Standards 42 & 53
and certified for a reduction in the substances cited
below.
The concentration of the indicated substances which
are dissolved in water and penetrate the system was
reduced to a value below or equal to the permitted limit
value in accordance with ANSI/NSF 42 and 53
for water discharged out of the appliance.
Note
Even though the tests were conducted under standard
laboratory conditions, the actual performance may
deviate from these tests.
* Based on the use of Cryptosporium parvum ocysts.
Application guidelines / Water supply parameters:
The system is to be installed and operated
according to the guidelines recommended by
the manufacturer.
The filter is to be changed every 6-9 months.
Rinse new filter thoroughly for 5 minutes.
More detailed information can be found on
the warranty card.
Without appropriate disinfection before and after
connecting it to the system, this product should NOT
be used if the water is microbiologically
contaminated or if the quality has not been
ascertained. A system certified for cyst reduction
should be used for disinfected water which possibly
contains filterable cysts.
A one-year warranty is issued for the entire system
(except disposable cartridge). With reference
to disposable cartridges a warranty is issued for
material and processing faults only. As the service life
of disposable cartridges depends on the local water
conditions, no warranty is issued for them.
More detailed information on the prices of spare parts
is available from your appliance dealer or parts
salesman on site.
Manufactured by:
3 M Material Technology (Guangzhou) Ltd.
9 Nanxiang Er road, Science City,
Guangzhou, 510663, P.R. China
The system was tested and certified on model
9000 225 170 by NSF International with reference
to ANSI/NSF Standard 53 for a reduction in cysts
and turbidity, as well as with reference to ANSI/NSF
Standard 42 for a reduction in the taste and odour
of chlorine.
Nominal particle class: I
Nominal service life: 2.800 litres
Substance Average in inflow Inflow concentration Waste water
concentration
Average reduction as
%
Max. permitted
concentration in waste
water
Max. waste
water
Min. reduction as % NSF test
Cysts * 166.500 Min. 50.000/l 1 99.99 99.95 1 99.99 511077-03
Turbidity 10.7 11 x 1 NTU 0.3 l 97.10 0.5 NTU 0.49 95.42 511078-03
Particle class I
Particle size
> 0.5
to < 1.0 μm
5.700.000 At least 10.000
particles/ml
30.583 99.52 > 85% 69.000 98.9 511079-03
Taste
of chlorine and
turbidity
1.9 2.0 mg/l + -10% 0.05 97.3 > 50% 0.06 96.84 511081-03
Water pressure 207 - 827 kPa
Water temperature * 0.6 °C - 38 °C
Flow rate 2.83 l/min.
52


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch KAD92HI30 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch KAD92HI30 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 8,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info