If the quick-clamping nut
has been attached correctly
and is not damaged, you
can loosen it by hand by
turning the knurled ring an-
ticlockwise. If the quick-
clamping nut is stuck, do
not attempt to loosen it
with pliers – always use
the two-pin spanner. Posi-
tion the two‑pin spanner as
shown in the figure.
Approved abrasive tools
You can use all the abrasive tools mentioned in these operat-
ing instructions.
The permissible speed [min-1] or the circumferential speed
[m/s] of the abrasive tools used must at least match the val-
ues given in the table.
It is therefore important to observe the permissible rota-
tional/circumferential speed on the label of the abrasive
tool.
max. [mm] [mm]
D b d [min-1] [m/s]
180
230
8
8
22.2
22.2
8500
6500
80
80
180
230
8500
6500
80
80
100 30 M 14 8500 45
Dust/Chip Extraction
The dust from materials such as lead paint, some types of
wood, minerals and metal can be harmful to human health.
Touching or breathing in this dust can trigger allergic reac-
tions and/or cause respiratory illnesses in the user or in
people in the near vicinity.
Certain dusts, such as oak or beech dust, are classified as
carcinogenic, especially in conjunction with wood treatment
additives (chromate, wood preservative). Materials contain-
ing asbestos may only be machined by specialists.
Use a dust extraction system that is suitable for the ma-
terial wherever possible.
Provide good ventilation at the workplace.
It is advisable to wear a P2 filter class breathing mask.
The regulations on the material being machined that apply in
the country of use must be observed.
uAvoid dust accumulation at the workplace. Dust can
easily ignite.
Operation
Start-Up
uPay attention to the mains voltage. The voltage of the
power source must match the voltage specified on the
rating plate of the power tool. Power tools marked
with 230V can also be operated with 220V.
uProducts that are only sold in AUS and NZ: Use a resid-
ual current device (RCD) with a nominal residual current
of 30 mA or less.
When operating the power tool using a mobile generator that
does not have sufficient reserve capacity or an adequate
voltage control system with inrush current boost converter,
loss of performance or atypical behaviour may occur upon
switch-on.
Please check the suitability of the power generator you are
using, particularly with regard to the mains voltage and fre-
quency.
uHold the tool by the insulated gripping surfaces and
auxiliary handle only. The application tool could come
into contact with hidden wiring or its own cord. Con-
tact with live wires may make metal parts of the tool live,
posing a risk of electric shock.
Switching on/off
To start the power tool, push the on/off switch (2) forward
and then press it down.
To lock the on/off switch (2) in position, push the on/off
switch (2) further forward.
To switch off the power tool, release the on/off switch (2);
or, if the switch is locked, briefly press the on/off switch (2)
and then release it.
uAlways check abrasive tools before using them. The
abrasive tool must be fitted properly and be able to
move freely. Carry out a test run for at least one
minute with no load. Do not use abrasive tools that are
damaged, run untrue or vibrate during use. Damaged
abrasive tools can burst apart and cause injuries.
Switch without locking mechanism (country-specific):
(GWS24-180P / GWS24-230P / GWS24-230PZ)
To start the power tool, push the on/off switch (2) forward
and then press it down.
To switch off the power tool, release the on/off switch (2).
Restart protection
(GWS24-180JZ / GWS24-230JZ / GWS24-230PZ)
The restart protection feature prevents the power tool from
uncontrolled starting after the power supply to it has been
interrupted.
To restart the tool, set the on/off switch (2) to the "off" posi-
tion and then switch the power tool on again.
Bosch Power Tools 1 609 92A 5TE | (29.07.2021)
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GWS 24-180 P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GWS 24-180 P in the language / languages: All languages as an attachment in your email.

The manual is 5.03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info