Technical Data
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the mea-
suring tool.
To open the battery compartment 3, turn the latch 2 in clock-
wise direction to position and pull off the battery lid.
Insert the batteries provided. When inserting, pay attention
to the correct polarity according to the representation on the
inside of the battery compartment.
Position the battery lid to the bottom of the housing and then
push it upward. To lock the battery lid, turn the latch 2 in anti-
clockwise direction to the position.
When the laser beams flash slowly during operation, the bat-
teries are low. When the flashing begins, the measuring tool
can be operated for approx. 8 h.
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
Remove the batteries from the measuring tool when
not using it for extended periods. When storing for
extended periods, the batteries can corrode and self-
discharge.
Operation
Initial Operation
Protect the measuring tool against moisture and direct
sun light.
Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. As an example, do
not leave it in vehicles for a long time. In case of large vari-
ations in temperature, allow the measuring tool to adjust to
the ambient temperature before putting it into operation.
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool can be impaired.
Avoid heavy impact to or falling down of the measuring
tool. Damage to the measuring tool can impair its accura-
cy. After heavy impact or shock, compare the laser lines or
plumb beams with a known horizontal or vertical reference
line or with already checked plumb points.
Switch the measuring tool off during transport. When
switching off, the levelling unit, which can be damaged in
case of intense movement, is locked.
Switching On and Off
To switch on the measuring tool, push the On/Off switch 4
upward so that “I” is indicated on the switch. Immediately
after switching on, the measuring tool sends a laser beam out
of each exit opening 1.
Do not point the laser beam at persons or animals and
do not look into the laser beam yourself, not even from
a large distance.
Do not leave the switched-on measuring tool unattend-
ed and switch the measuring tool off after use. Other
persons could be blinded by the laser beam.
To switch off the measuring tool, push the On/Off switch 4
downward so that “0” is indicated on the switch. When
switching off, the levelling unit is locked.
Setting the Automatic Switch-off
By default, the measuring tool automatically shuts off
20 minutes after being switched on.
The automatic switch-off can be set from 20 minutes to
8 hours. For this, switch the measuring tool on, then immedi-
ately off, and then on again within 4 s. To confirm the change,
all laser beams will flash quickly for 2 s after switching on the
second time.
When switching on the measuring tool the next time, the auto-
matic switch-off is set to 20 minutes again.
Working with Automatic Levelling
Position the measuring tool on a level and firm support, attach
it to the holder 8 or to the tripod 18.
After switching on, the automatic levelling function automati-
cally compensates irregularities within the self-levelling range
of ±5° (longitudinal axis) and ±3° (lateral axis). The levelling
is finished as soon as the laser points do not move any more.
If the automatic levelling function is not possible, e.g. be-
cause the surface on which the measuring tool stands devi-
ates by more than 5 ° or 3° from the horizontal plane, the laser
Point Laser GPL 5
Article number
3 601 K66 2..
Working range
30 m
Levelling Accuracy
±0.3 mm/m
Self-levelling range (typical)
alongside the
longitudinal axis
lateral axis
±5°
±3°
Levelling duration, typically <4s
Operating temperature
–10°C...+40°C
Storage temperature
–20°C...+70°C
Relative air humidity, max.
90 %
Laser class
2
Laser type
635 nm, <1 mW
Tripod mount
1/4"
Batteries
3 x 1.5 V LR06 (AA)
Operating time, approx.
24 h
Weight according to
EPTA-Procedure 01/2003
0.25 kg
Dimensions (length x width x
height)
104 x 40 x 80 mm
Degree of protection
IP 5X
The measuring tool can be clearly identified with the serial number 7 on
the type plate.
OBJ_BUCH-815-003.book Page 10 Thursday, May 15, 2014 10:51 AM
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GPL 5 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GPL 5 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 8,91 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info