544288
13
Zoom out
Zoom in
Previous page
1/220
Next page
English | 13
Bosch Power Tools 1 609 92A 0KL | (12.5.14)
Technical Data
Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the meas-
uring tool.
To open the battery lid 10, slide the latch 11 in the direction
of the arrow and fold the battery lid up. Insert the batteries.
When inserting, pay attention to the correct polarity accord-
ing to the representation on the inside of the battery lid.
When the batteries become weak, a single 5 s audio signal will
sound. The battery low indicator 2 continuously flashes red.
The measuring tool can be operated for less then 2 h.
If the batteries are weak when switching on the measuring
tool, the 5 s audio signal will sound directly after switching on
the measuring tool.
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
Remove the batteries from the measuring tool when
not using it for extended periods. When storing for
extended periods, the batteries can corrode and self-
discharge.
Operation
Initial Operation
Loud audio signals will sound under certain conditions
while operating the measuring tool. Therefore, keep
the measuring tool away from your ear or other per-
sons. The loud audio signal can cause hearing damage.
Protect the measuring tool against moisture and direct
sun light.
Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. As an example, do
not leave it in vehicles for a long time. In case of large vari-
ations in temperature, allow the measuring tool to adjust to
the ambient temperature before putting it into operation.
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool can be impaired.
Avoid heavy impact or falling of the measuring tool. Af-
ter heavy exterior impact on the measuring tool, an accura-
cy check should always be carried out before continuing to
work (see “Levelling Accuracy”).
Switch the measuring tool off during transport. When
switching off, the levelling unit, which can be damaged in
case of intense movement, is locked.
Switching On and Off
To switch on the measuring tool, slide the On/Off switch 7 to
the “on position (when working without automatic level-
ling) or to the “on position (when working with automat-
ic levelling). Immediately after switching on, the measuring
tool sends laser beams out of the exit openings 1.
Do not point the laser beam at persons or animals and
do not look into the laser beam yourself, not even from
a large distance.
Do not leave the switched-on measuring tool unattend-
ed and switch the measuring tool off after use. Other
persons could be blinded by the laser beam.
To switch off the measuring tool, slide the On/Off switch 7 to
the “off” position. When switching off, the levelling unit is
locked.
When exceeding the maximum permitted operating tempera-
ture of 40 °C, the measuring tool switches off to protect the
laser diode. After cooling down, the measuring tool is ready
for operation and can be switched on again.
Deactivating the Automatic Shut-off
When no button on the measuring tool is pressed for approx.
30 minutes, the measuring tool automatically switches off to
save the batteries.
To switch on the measuring tool after automatic shut-off,
either slide the On/Off switch 7 to the “off” position and then
switch the measuring tool on again or press the operating
mode button 5 once or press the pulse-function button 3
once.
Line laser GLL 3-80 P
Article number
3 601 K63 300
Working range
1)
–Standard
With pulse function
–With laser receiver
20 m
15 m
5–80m
Levelling Accuracy
±0.2mm/m
Self-levelling range, typically
±4°
Levelling duration, typically
<4s
Operating temperature
10 °C ... +40 °C
Storage temperature
20 °C ... +70 °C
Relative air humidity, max.
90 %
Laser class
2
Laser type
640 nm, <1 mW
C
6
1
Shortest pulse duration
1/1600 s
Tripod mount
1/4", 5/8"
Batteries
4 x 1.5 V LR06 (AA)
Operating duration
–With 3 laser planes
–With 2 laser planes
–With 1 laser plane
5h
9h
18 h
Weight according to EPTA-Procedure
01/2003
0.75 kg
Dimensions (length x width x height)
159 x 75 x 141 mm
Degree of protection
IP 54 (dust and
splash water
protected)
1) The working range can be decreased by unfavourable environmental
conditions (e.g. direct sun irradiation).
The measuring tool can be clearly identified with the serial number 13
on the type plate.
OBJ_DOKU-32907-002.fm Page 13 Monday, May 12, 2014 12:52 PM
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GLL 3-80 P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GLL 3-80 P in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 22,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info