Assembly
Inserting/Replacing the Batteries
Alkali-manganese batteries are recommended for the mea-
suring tool.
To open the battery lid 10, slide the latch 11 in the direction
of the arrow and fold the battery lid up. Insert the batteries.
When inserting, pay attention to the correct polarity accord-
ing to the representation on the inside of the battery lid.
When the batteries become weak, a single 5 s audio signal will
sound. The battery low indicator 2 continuously flashes red.
The measuring tool can be operated for less then 2 h.
If the batteries are weak when switching on the measuring
tool, the 5 s audio signal will sound directly after switching on
the measuring tool.
Always replace all batteries at the same time. Only use batter-
ies from one brand and with the identical capacity.
Remove the batteries from the measuring tool when
not using it for extended periods. When storing for ex-
tended periods, the batteries can corrode and self-dis-
charge.
Operation
Initial Operation
Loud audio signals will sound under certain conditions
while operating the measuring tool. Therefore, keep
the measuring tool away from your ear or other per-
sons. The loud audio signal can cause hearing damage.
Protect the measuring tool against moisture and direct
sun light.
Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. As an example, do
not leave it in vehicles for a long time. In case of large vari-
ations in temperature, allow the measuring tool to adjust to
the ambient temperature before putting it into operation.
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool can be impaired.
Avoid heavy impact to or falling down of the measuring
tool. Damage to the measuring tool can impair its accura-
cy. After heavy impact or shock, compare the laser lines or
plumb beams with a known horizontal or vertical reference
line or with already checked plumb points.
Switch the measuring tool off during transport. When
switching off, the levelling unit, which can be damaged in
case of intense movement, is locked.
Switching On and Off
To switch on the measuring tool, slide the On/Off switch 7 to
the “on position (when working without automatic level-
ling) or to the “on position (when working with automat-
ic levelling). Immediately after switching on, the measuring
tool sends laser beams out of the exit openings 1.
Do not point the laser beam at persons or animals and
do not look into the laser beam yourself, not even from
a large distance.
Do not leave the switched-on measuring tool unattend-
ed and switch the measuring tool off after use. Other
persons could be blinded by the laser beam.
To switch off the measuring tool, slide the On/Off switch 7 to
the “off” position. When switching off, the levelling unit is
locked.
When exceeding the maximum permitted operating tempera-
ture of 45 °C, the measuring tool switches off to protect the
laser diode. After cooling down, the measuring tool is ready
for operation and can be switched on again.
Deactivating the Automatic Shut-off
When no button on the measuring tool is pressed for approx.
30 minutes, the measuring tool automatically switches off to
save the batteries.
To switch on the measuring tool after automatic shut-off, ei-
ther slide the On/Off switch 7 to the “off” position and then
switch the measuring tool on again or press the operating
mode button 5 once or press the pulse-function button 3
once.
To deactivate the automatic shut-off, keep the operating
mode button 5 pressed for at least 3 s (while the measuring
tool is switched on). Deactivation of the automatic shut-off is
confirmed by brief flashing of the laser beams.
To activate the automatic shut-off, switch the measuring tool
off and then on again or press and hold the operating mode
button 5 for at least 3 s.
Deactivating the Signal Tone
After the measuring tool has been switched on, the audio sig-
nal is always activated.
To deactivate/activate the audio signal, press and hold the
operating mode button 5 and the pulse-function button 3 at
the same time for at least 3 s.
The audio signal activation and deactivation are both con-
firmed by three short beeps.
Operating Modes
The measuring tool has three operating modes between
which you can switch at any time:
Horizontal operation: generates a horizontal laser plane,
Vertical operation: generates a vertical laser plane,
Cross-line operation: generates a horizontal and vertical
laser plane.
Dimensions
(length x width x height)
159 x 54 x 141 mm
Degree of protection
IP 54 (dust and splash
water protected)
Line laser GLL 2-80 P
1) The working range can be decreased by unfavourable environmental
conditions (e.g. direct sun irradiation).
The measuring tool can be clearly identified with the serial number 13
on the type plate.
OBJ_BUCH-907-003.book Page 13 Wednesday, May 7, 2014 1:39 PM
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Bosch GLL 2-80 P at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Bosch GLL 2-80 P in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 23,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info